Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method?

被引:112
作者
Bleiziffer, Sabine [1 ]
Eichinger, Walter B. [1 ]
Hettich, Ina [1 ]
Guenzinger, Ralf [1 ]
Ruzicka, Daniel [1 ]
Bauernschmitt, Robert [1 ]
Lange, Ruediger [1 ]
机构
[1] German Heart Ctr, Clin Cardiovas Surg, D-80636 Munich, Germany
关键词
D O I
10.1136/hrt.2006.102764
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To predict the occurrence of valve prosthesis-patient mismatch ( VP-PM) after aortic valve replacement ( AVR), the surgeon needs to estimate the postoperative effective orifice area index ( EOAI). Aim: To compare different methods of predicting VP-PM. Methods: The effective orifice area ( EOA) of 383 patients who had undergone AVR between July 2000 and January 2005 with various aortic valve prostheses was obtained echocardiographically 6 months after the operation. We tested the efficacy of ( 1) EOAI calculated from the echo data obtained in our own laboratory, ( 2) indexed geometric orifice area, ( 3) EOAI estimated from charts provided by prosthesis manufacturers ( which are based either on in vitro or on echo data) and ( 4) EOAI estimated from reference echo data published in the literature to predict VP-PM. Results: Sensitivity and specificity to predict VP-PM were 53% and 83% ( method 1), 80% and 53% ( charts based on echo data, parts of method 3) and 71% and 67% ( method 4) using reference data derived from echocardiographic examinations. The sensitivity of method 2 and of charts based on in vitro data ( parts of method 3) to predict VP-PM was 0-17%. The incidence of severe VP-PM could be reduced from 8.7% to 0.8% after the introduction of the systematic estimation of the EOAI at the time of operation ( p = 0.003, method 1). Conclusions: The best method of predicting VP-PM is the use of mean ( SD) EOAs derived from echocardiographic examinations, whereas the use of in vitro data or the geometric orifice area is unreliable. After the surgeon's anticipation of VP-PM prior to AVR, the incidence of VP-PM could be reduced.
引用
收藏
页码:615 / 620
页数:6
相关论文
共 31 条
[1]   Prosthesis size and long-term survival after aortic valve replacement [J].
Blackstone, EH ;
Cosgrove, DM ;
Jamieson, WRE ;
Birkmeyer, NJ ;
Lemmer, JH ;
Miller, DC ;
Butchart, EG ;
Rizzoli, G ;
Yacoub, M ;
Chai, AK .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) :783-796
[2]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[3]  
Bonow R O, 1998, J Heart Valve Dis, V7, P672
[4]   Comparison of bioprostheses in patients with small aortic annulus - Reply [J].
Botzenhardt, F ;
Eichinger, WB ;
Bleiziffer, S ;
Guenzinger, R ;
Wagner, IM ;
Bauernschmitt, R ;
Lange, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (05) :1088-1088
[5]   Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular Perimount Magna bioprosthesis in the aortic position [J].
Botzenhardt, F ;
Eichinger, WB ;
Guenzinger, R ;
Bleiziffer, S ;
Wagner, I ;
Bauernschmitt, R ;
Lange, R .
THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (04) :226-230
[6]   Hemodynamic comparison of Bioprostheses for complete supra-annular position in patients with small aortic annulus [J].
Botzenhardt, F ;
Eichinger, WB ;
Bleiziffer, S ;
Guenzinger, R ;
Wagner, IM ;
Bauernschmitt, R ;
Lange, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (12) :2054-2060
[7]  
Fernandez J, 1996, CIRCULATION, V94, P109
[8]   Prosthesis-patient mismatch is not clinically relevant in aortic valve replacement using the Carpentier-Edwards Perimount valve [J].
Flameng, Willem ;
Meuris, Bart ;
Herijgers, Paul ;
Herregods, Marie-Christine .
ANNALS OF THORACIC SURGERY, 2006, 82 (02) :530-536
[9]   Mosaic valve international clinical trial: Early performance results [J].
Fradet, GJ ;
Bleese, N ;
Burgess, J ;
Cartier, PC .
ANNALS OF THORACIC SURGERY, 2001, 71 (05) :S273-S277
[10]   Patient-prosthesis mismatch does not affect survival following aortic valve replacement [J].
Howell, Neil J. ;
Keogh, Bruce E. ;
Barnet, Vivien ;
Bonser, Robert S. ;
Graham, Timothy R. ;
Rooney, Stephen J. ;
Wilson, Ian C. ;
Pagano, Domenico .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 30 (01) :10-14