Effect of physical exercise on cartilage volume and thickness in vivo: MR imaging study

被引:95
作者
Eckstein, F [1 ]
Tieschky, M
Faber, SC
Haubner, M
Kolem, H
Englmeier, KH
Reiser, M
机构
[1] Univ Munich, Klinikum Grosshadern, Inst Diagnost Radiol, D-8000 Munich, Germany
[2] Univ Munich, Inst Anat, D-80336 Munich, Germany
[3] GSF Forschungszentrum Umwelt & Gesundheit, Inst Med Comp Sci, Oberschleissheim, Germany
[4] Siemens AG, Dept MR Applicat, D-8520 Erlangen, Germany
关键词
cartilage; MR; magnetic resonance (MR); three-dimensional; volume measurement;
D O I
10.1148/radiology.207.1.9530322
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To quantify, with magnetic resonance (MR) imaging, the in vivo changes in cartilage volume and thickness after physical exercise. MATERIALS AND METHODS: The patellae of eight volunteers were imaged six times at physical rest by using a spoiled fat-suppressed gradient-echo sequence with an acquisition time of 4.10 minutes. The volunteers then performed 50 knee bends, and two more data sets were acquired 3-7 minutes and 8-12 minutes after exercise. The patellar cartilage volume was determined after three-dimensional reconstruction, and the thickness was assessed with a three-dimensional minimal-distance algorithm. RESULTS: Whereas repositioning had a small effect on the measurements (mean coefficient of variation, 1.4%), a statistically significant decrease in cartilage volume was observed 3-7 minutes (mean decrease, 6.0%; P < .05) and 8-12 minutes (mean decrease, 5.2%; P < .05) after exercise. The deformation was homogeneous throughout the joint surface. In one asymptomatic volunteer, a cartilage lesion became more pronounced after exercise. CONCLUSION: MR imaging can be used to investigate the response of articular cartilage to physical exercise in vivo. Patients or volunteers should be allowed a sufficient period of physical rest if quantitative measurements of cartilage volume and thickness are to be undertaken in longitudinal studies.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 29 条
  • [1] TENSILE PROPERTIES OF HUMAN KNEE-JOINT CARTILAGE .1. INFLUENCE OF IONIC CONDITIONS, WEIGHT BEARING, AND FIBRILLATION ON THE TENSILE MODULUS
    AKIZUKI, S
    MOW, VC
    MULLER, F
    PITA, JC
    HOWELL, DS
    MANICOURT, DH
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1986, 4 (04) : 379 - 392
  • [2] VARIATIONS IN THE INTRINSIC MECHANICAL PROTERTIES OF HUMAN ARTICULAR-CARTILAGE WITH AGE, DEGENERATION, AND WATER-CONTENT
    ARMSTRONG, CG
    MOW, VC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (01) : 88 - 94
  • [3] INTERSPECIES COMPARISONS OF INSITU INTRINSIC MECHANICAL-PROPERTIES OF DISTAL FEMORAL CARTILAGE
    ATHANASIOU, KA
    ROSENWASSER, MP
    BUCKWALTER, JA
    MALININ, TI
    MOW, VC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (03) : 330 - 340
  • [4] COHEN ZA, 1997, T ORTHOP RES SOC, V22, P625
  • [5] SHOULD PERIMENOPAUSAL WOMEN BE SCREENED FOR OSTEOPOROSIS
    CUMMINGS, SR
    BLACK, D
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 104 (06) : 817 - 823
  • [6] Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)
    Eckstein, F
    Gavazzeni, A
    Sittek, H
    Haubner, M
    Losch, A
    Milz, S
    Englmeier, KH
    Schulte, E
    Putz, R
    Reiser, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) : 256 - 265
  • [7] Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging
    Eckstein, F
    Adam, C
    Sittek, H
    Becker, C
    Milz, S
    Schulte, E
    Reiser, M
    Putz, R
    [J]. JOURNAL OF BIOMECHANICS, 1997, 30 (03) : 285 - 289
  • [8] Magnetic resonance chondro-crassometry (MR CCM): A method for accurate determination of articular cartilage thickness
    Eckstein, F
    Sittek, H
    Gavazzeni, A
    Schulte, E
    Milz, S
    Kiefer, B
    Reiser, M
    Putz, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) : 89 - 96
  • [9] ECKSTEIN F, IN PRESS AJR
  • [10] EKHOLM R, 1952, Acta Soc Med Ups, V57, P39