Comparison between prospective and retrospective triggering for mouse cardiac MRI

被引:84
作者
Heijman, Edwin
de Graaf, Wolter
Niessen, Petra
Nauerth, Arno
van Eys, Guillaume
de Graaf, Larry
Nicolay, Klaas
Strijkers, Gustav J.
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Biomed NMR, NL-5600 MB Eindhoven, Netherlands
[2] Univ Maastricht, CARIM, Dept Mol Genet, Maastricht, Netherlands
[3] Bruker Biospin MRI GmbH, Ettingen, Germany
关键词
MRI; heart; mouse; triggering; navigator; retrospective; self-gated;
D O I
10.1002/nbm.1110
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
High-resolution magnetic resonance imaging (MRI) has evolved into one of the major non-invasive tools to study the healthy and diseased mouse heart. This study presents a Cartesian CINE MRI protocol based on a fast low-angle shot sequence with a navigator echo to generate cardiac triggering and respiratory gating signals retrospectively, making the use of ECG leads and respiratory motion sensors obsolete. MRI of the in vivo mouse heart using this sequence resulted in CINE images with no detectable cardiac and respiratory motion artefacts. The retrospective method allows for steady-state imaging of the mouse heart, which is essential for quantitative contrast-enhanced MRI studies. A comparison was made between prospective and retrospective methods in terms of the signal-to-noise ratio and the contrast-to-noise ratio between blood and myocardial wall, as well as global cardiac functional indices: end-diastolic volume, end-systolic volume, stroke volume and ejection fraction. The retrospective method resulted in almost constant left-ventricle wall signal intensity throughout the cardiac cycle, at the expense of a decrease in the signal-to-noise ratio and the contrast-to-noise ratio between blood and myocardial wall as compared with the prospective method. Prospective and retrospective sequences yielded comparable global cardiac functional indices. The largest mean relative difference found was 8% for the end-systolic volume. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:439 / 447
页数:9
相关论文
共 27 条
[1]
Black blood gradient echo cine magnetic resonance imaging of the mouse heart [J].
Berr, SS ;
Roy, RJ ;
French, BA ;
Yang, ZQ ;
Gilson, W ;
Kramer, CM ;
Epstein, FH .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) :1074-1079
[2]
Retrospective gating for mouse cardiac MRI [J].
Bishop, J ;
Feintuch, A ;
Bock, NA ;
Nieman, B ;
Dazai, J ;
Davidson, L ;
Henkelman, RM .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :472-477
[3]
Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging [J].
Brau, ACS ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) :263-270
[4]
Assessment of motion gating strategies for mouse magnetic resonance at high magnetic fields [J].
Cassidy, PJ ;
Schneider, JE ;
Grieve, SM ;
Lygate, C ;
Neubauer, S ;
Clarke, K .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (02) :229-237
[5]
Automated rectilinear self-gated cardiac cine imaging [J].
Crowe, ME ;
Larson, AC ;
Zhang, Q ;
Carr, J ;
White, RD ;
Li, DB ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :782-788
[6]
MAGNETIC-RESONANCE IMAGING WITH RESPIRATORY GATING - TECHNIQUES AND ADVANTAGES [J].
EHMAN, RL ;
MCNAMARA, MT ;
PALLACK, M ;
HRICAK, H ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1175-1182
[7]
MR tagging early after myocardial infarction in mice demonstrates contractile dysfunction in adjacent and remote regions [J].
Epstein, FH ;
Yang, ZQ ;
Gilson, WD ;
Berr, SS ;
Kramer, CM ;
French, BA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :399-403
[8]
RAPID NMR IMAGING OF DYNAMIC PROCESSES USING THE FLASH TECHNIQUE [J].
FRAHM, J ;
HAASE, A ;
MATTHAEI, D .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :321-327
[9]
Magnetic resonance imaging accurately estimates LV mass in a transgenic mouse model of cardiac hypertrophy [J].
Franco, F ;
Dubois, SK ;
Peshock, RM ;
Shohet, RV .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1998, 274 (02) :H679-H683
[10]
HEIJMAN E, 2006, P INT SOC MAGN RESON, V14