A study of the directional response of ultraviolet radiometers: II. Implications for ultraviolet phototherapy derived from computer simulations

被引:18
作者
Martin, CJ
Pye, SD
机构
[1] N Glasgow Univ Hosp NHS Trust, Western Infirm, Dept Clin Phys & Bioengn, Glasgow G11 6NT, Lanark, Scotland
[2] Western Gen Hosp, Dept Med Phys & Med Engn, Edinburgh EH4 2XU, Midlothian, Scotland
关键词
Computer simulation - Dosimetry - Radiotherapy - Ultraviolet radiation;
D O I
10.1088/0031-9155/45/9/320
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A theoretical model has been used to simulate irradiances for ultraviolet (UV) phototherapy cabinets and other sources. The accuracy of the simulation results has been checked by comparison with experimental measurements. The simulations have been used to study the influence of different factors on UV phototherapy exposure and to develop recommendations for the operation and calibration of phototherapy cabinets. Many radiometers used in the evaluation of skin doses have input optics with directional responses that are not proportional to the cosine of the angle of incidence for the UV radiation. Data on radiometer directional responses have been incorporated into the simulations, which show that the poor directional responses for some radiometers currently in use will give errors of 20-50% in the assessment of irradiance. The influence of lamp source geometries employed for radiometer calibration has been investigated. UV phototherapy dosimetry commonly uses a spectroradiometer and a radiometer in the transfer of irradiance calibrations from a small standard UV lamp to a large-area source with a different UV spectrum. Recommendations are given on the range of acceptability for radiometer directional responses and a method is described for determining whether these are fulfilled. Recommendations are made on the techniques that should be used for calibration.
引用
收藏
页码:2713 / 2729
页数:17
相关论文
共 14 条
[1]   An appraisal of narrowband (TL-01) UVB phototherapy. British Photodermatology Group Workshop Report (April 1996) [J].
Bilsland, D ;
Dawe, R ;
Diffey, BL ;
Farr, P ;
Ferguson, J ;
George, S ;
Gibbs, NK ;
Green, C ;
McGregor, J ;
VanWeelden, H ;
Wainwright, NJ ;
Young, AR .
BRITISH JOURNAL OF DERMATOLOGY, 1997, 137 (03) :327-330
[2]  
*CIE, 1987, CIE PUBL, V69
[3]   Traceable calibration of ultraviolet meters used with broadband, extended sources [J].
Coleman, AJ ;
Collins, M ;
Saunders, JE .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01) :185-196
[4]  
Diffey B., 1997, 76 IPEM
[5]   COMPARISON OF ANATOMICAL UNIFORMITY OF IRRADIATION IN 2 DIFFERENT PHOTOCHEMOTHERAPY UNITS [J].
DIFFEY, BL ;
HARRINGTON, TR ;
CHALLONER, AVJ .
BRITISH JOURNAL OF DERMATOLOGY, 1978, 99 (04) :361-363
[6]  
GIBSON P, 1989, RAD MEASUREMENT PHOT, P71
[7]   ULTRAVIOLET-RADIATION IN THE TREATMENT OF SKIN-DISEASE [J].
GREEN, C ;
DIFFEY, BL ;
HAWK, JLM .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :1-20
[8]  
Hawk JLM, 1999, PHOTODERMATOLOGY
[9]  
HOLMES MG, 1989, RAD MEASUREMENT PHOT, P85
[10]  
Lange F, 1998, TECH RISK S, V12, P207