Multienzyme electrochemical array sensor for determination of phenols and pesticides

被引:52
作者
Solná, R
Sapelnikova, S
Skládal, P
Winther-Nielsen, M
Carlsson, C
Emnéus, J
Ruzgas, T
机构
[1] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
[2] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[3] DHI, Water & Environm, DK-2970 Horsholm, Denmark
[4] ANOX, S-22647 Lund, Sweden
关键词
amperometric screen-printed biosensor; flow-injection analysis; steady state system; tyrosinase; peroxidase; cholinesterase; phenols; pesticides; wastewater;
D O I
10.1016/j.talanta.2004.07.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The screen-printed four-electrode system was used as the amperometric transducer for determination of phenols and pesticides using immobilised tyrosinase. peroxidase. acetylcholinesterase and butyrylcholinesterase. Acetylthiocholine chloride was chosen as substrate for cholinesterases to measure inhibition by pesticides, hydrogen peroxide served as co-substrate for peroxidase to measure phenols. The compatibility of hydrolases and oxidoreductases working in the same array was studied. The detection of p-cresol, catechol and phenol as well as of pesticides including carbaryl, heptenophos and fenitrothion was carried out in flow-through and steady state arrangements. In addition. the effects of heavy metals (CL2+, Cd2+, Fe3+), fluoride (NaF), benzene and dimethylsulphoxide on cholinesterase activities ere evaluated. It was demonstrated that electrodes modified with hydrolases and oxidoreductases can function in the same array. The achieved R.S.D. values obtained for the flow system were below 4% for the same sensor and less than 10% within a group of five sensors. For the steady state system, R.S.D.s were approximately twice higher. One assay was completed in less than 6 min. The limit of detection for catechol Using tyrosinase was equal to 0.35 and 1.7 muM in the flow and steady state systems, respectively. On the contrary, lower limits of detection for pesticides were achieved in the steady state system-carbaryl 26 W, heptenophos 14 nM and fenitrothion 0.58 muM. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:349 / 357
页数:9
相关论文
共 52 条
[11]   Hydrogen peroxide sensitive biosensor based on plant peroxidases entrapped in Os-modified polypyrrole films [J].
Gaspar, S ;
Habermüller, K ;
Csöregi, E ;
Schuhmann, W .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (01) :63-68
[12]  
GRUSS R, 1989, ANAL LETT, V22, P1159
[13]  
HAGNIGNI B, 2003, ANAL CHIM ACTA, V487, P3
[14]   Direct electrochemistry and electrocatalysis with horseradish peroxidase in Eastman AQ films [J].
Huang, R ;
Hu, NF .
BIOELECTROCHEMISTRY, 2001, 54 (01) :75-81
[15]   REVERSIBLE INHIBITION OF BUTYRYLCHOLINESTERASE WITH AROMATIC-HYDROCARBONS [J].
JARV, J ;
SPEEK, M .
BIOCHIMICA ET BIOPHYSICA ACTA, 1982, 706 (02) :174-178
[16]   Separation-free electrochemical immunosensor for rapid determination of atrazine [J].
Keay, RW ;
McNeil, CJ .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (09) :963-970
[17]   Determination of binary pesticide mixtures by an acetylcholinesterase-choline oxidase biosensor [J].
Kok, FN ;
Hasirci, V .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (07) :661-665
[18]   AMPEROMETRIC FLOW-THROUGH BIOSENSOR FOR THE DETERMINATION OF PESTICIDES [J].
LAROSA, C ;
PARIENTE, F ;
HERNANDEZ, L ;
LORENZO, E .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :129-136
[19]  
LEONI V, 1992, J AOAC INT, V75, P511
[20]   Amperometric detection of phenols using peroxidase-modified graphite electrodes [J].
Lindgren, A ;
Emneus, J ;
Ruzgas, T ;
Gorton, L ;
MarkoVarga, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :51-62