Multienzyme electrochemical array sensor for determination of phenols and pesticides

被引:52
作者
Solná, R
Sapelnikova, S
Skládal, P
Winther-Nielsen, M
Carlsson, C
Emnéus, J
Ruzgas, T
机构
[1] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
[2] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[3] DHI, Water & Environm, DK-2970 Horsholm, Denmark
[4] ANOX, S-22647 Lund, Sweden
关键词
amperometric screen-printed biosensor; flow-injection analysis; steady state system; tyrosinase; peroxidase; cholinesterase; phenols; pesticides; wastewater;
D O I
10.1016/j.talanta.2004.07.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The screen-printed four-electrode system was used as the amperometric transducer for determination of phenols and pesticides using immobilised tyrosinase. peroxidase. acetylcholinesterase and butyrylcholinesterase. Acetylthiocholine chloride was chosen as substrate for cholinesterases to measure inhibition by pesticides, hydrogen peroxide served as co-substrate for peroxidase to measure phenols. The compatibility of hydrolases and oxidoreductases working in the same array was studied. The detection of p-cresol, catechol and phenol as well as of pesticides including carbaryl, heptenophos and fenitrothion was carried out in flow-through and steady state arrangements. In addition. the effects of heavy metals (CL2+, Cd2+, Fe3+), fluoride (NaF), benzene and dimethylsulphoxide on cholinesterase activities ere evaluated. It was demonstrated that electrodes modified with hydrolases and oxidoreductases can function in the same array. The achieved R.S.D. values obtained for the flow system were below 4% for the same sensor and less than 10% within a group of five sensors. For the steady state system, R.S.D.s were approximately twice higher. One assay was completed in less than 6 min. The limit of detection for catechol Using tyrosinase was equal to 0.35 and 1.7 muM in the flow and steady state systems, respectively. On the contrary, lower limits of detection for pesticides were achieved in the steady state system-carbaryl 26 W, heptenophos 14 nM and fenitrothion 0.58 muM. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:349 / 357
页数:9
相关论文
共 52 条
[31]   P-32 ANALYSIS OF DNA ADDUCTS IN TISSUES OF BENZENE-TREATED RATS [J].
REDDY, MV ;
BLACKBURN, GR ;
SCHREINER, CA ;
MEHLMAN, MA ;
MACKERER, CR .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1989, 82 :253-257
[32]   Biosensor for phenol based on the direct electron transfer blocking of peroxidase immobilising on silica-titanium [J].
Rosatto, SS ;
Kubota, LT ;
Neto, GD .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :65-72
[33]   THE DEVELOPMENT OF A PEROXIDASE BIOSENSOR FOR MONITORING PHENOL AND RELATED AROMATIC-COMPOUNDS [J].
RUZGAS, T ;
EMNEUS, J ;
GORTON, L ;
MARKOVARGA, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :245-253
[34]   Peroxidase-modified electrodes: Fundamentals and application [J].
Ruzgas, T ;
Csoregi, E ;
Emneus, J ;
Gorton, L ;
MarkoVarga, G .
ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) :123-138
[35]   KINETIC-MODELS OF HORSERADISH-PEROXIDASE ACTION ON A GRAPHITE ELECTRODE [J].
RUZGAS, T ;
GORTON, L ;
EMNEUS, J ;
MARKOVARGA, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 391 (1-2) :41-49
[36]   Screen-printed multienzyme arrays for use in amperometric batch and flow systems [J].
Sapelnikova, S ;
Dock, E ;
Solná, R ;
Skládal, P ;
Ruzgas, T ;
Emnéus, J .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (07) :1098-1103
[37]   Composite electrochemical biosensors:: a comparison of three different electrode matrices for the construction of amperometric tyrosinase biosensors [J].
Serra, B ;
Jiménez, S ;
Mena, ML ;
Reviejo, AJ ;
Pingarrón, JM .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :217-226
[38]   DETERMINATION OF ORGANOPHOSPHATE AND CARBAMATE PESTICIDES USING A COBALT PHTHALOCYANINE-MODIFIED CARBON PASTE ELECTRODE AND A CHOLINESTERASE ENZYME MEMBRANE [J].
SKLADAL, P .
ANALYTICA CHIMICA ACTA, 1991, 252 (1-2) :11-15
[39]   Detection of carbamate pesticides in vegetable samples using cholinesterase-based biosensors [J].
Skladal, P ;
Nunes, GS ;
Yamanaka, H ;
Ribeiro, ML .
ELECTROANALYSIS, 1997, 9 (14) :1083-1087
[40]   Detection of pesticides in the environment using biosensors based on cholinesterases [J].
Skladal, P ;
Fiala, M ;
Krejci, J .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 65 (1-4) :139-148