The InFOC/μS hard X-ray telescope:: Pixellated CZT detector/shield performance and flight results

被引:9
作者
Baumgartner, WH [1 ]
Tueller, J [1 ]
Krimm, H [1 ]
Barthelmy, S [1 ]
Berendse, F [1 ]
Ryan, L [1 ]
Birsa, F [1 ]
Okajima, T [1 ]
Kunieda, H [1 ]
Ogasaka, Y [1 ]
Tawara, Y [1 ]
Tamura, K [1 ]
机构
[1] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
来源
X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2 | 2003年 / 4851卷
关键词
CZT; background; shielding; balloon flights; hard X-ray astronomy; instrumentation;
D O I
10.1117/12.461491
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The CZT detector on the InFOCmuS hard X-ray telescope is a pixellated solid-state device capable of imaging spectroscopy by measuring the position and energy of each incoming photon. The detector sits at the focal point of an 8m focal length multilayered grazing incidence X-ray mirror which has significant effective area between 20-40 keV. The detector has an energy resolution of 4.0keV at 32keV, and the InFOCmuS telescope has an angular resolution of 2.2 arcminute and a field of view of about 10 arcminutes. InFOCmuS flew on a balloon mission in July 2001 and observed Cygnus X-1. We present results from laboratory testing of the detector to measure the uniformity of response across the detector, to determine the spectral resolution, and to perform a simple noise decomposition. We also present a hard X-ray spectrum and image of Cygnus X-1, and measurements of the hard X-ray CZT background obtained with the SWIN detector on InFOCmuS.
引用
收藏
页码:945 / 956
页数:12
相关论文
共 13 条
[1]  
BERENDSE F, 2002, UNPUB APPL OPTICS
[2]   Balloon flight background measurement with actively-shielded planar and imaging CZT detectors [J].
Bloser, PF ;
Narita, T ;
Jenkins, JA ;
Perrin, M ;
Murray, R ;
Grindlay, JE .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XII, 2002, 4497 :88-99
[3]  
DOBEREINER S, 1995, ASTRON ASTROPHYS, V302, P115
[4]   Development of the High-Energy Focusing Telescope (HEFT) balloon experiment [J].
Harrison, FA ;
Boggs, SE ;
Bolotnikov, A ;
Christensen, FE ;
Cook, WR ;
Craig, WW ;
Hailey, CJ ;
Jimenez-Garate, M ;
Mao, PH ;
Schindler, SE ;
Windt, DL .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 :693-699
[5]  
MARKS DA, 2000, THESIS U ARIZONA
[6]  
OGASAKA Y, 2002, P SPIE, V4851
[7]  
OKJAIMA T, 2002, IN PRESS APPL OPTICS
[8]   Characterization and performance of the InFOCμS 20-40 keV x-ray focusing mirror [J].
Owens, SM ;
Berendse, F ;
Okajima, T ;
Misaki, K ;
Ogasaka, Y ;
Tamura, K ;
Tawara, Y ;
Kunieda, H ;
Chan, KW ;
Soong, Y ;
Baumgartner, WH ;
Krimm, H ;
Tueller, J ;
Serlemitsos, PJ ;
Yamashita, K ;
Haga, K ;
Ichimaru, S ;
Takahashi, S ;
Gotou, A ;
Kitou, H ;
Fukuda, S ;
Kamata, Y ;
Furuzawa, A ;
Akimoto, F ;
Yoshioka, T ;
Kondou, K ;
Haba, Y ;
Tanaka, T .
X-RAY OPTICS FOR ASTRONOMY: TELESCOPES, MULTILAYERS, SPECTROMETERS, AND MISSIONS, 2002, 4496 :115-126
[9]   The effect of twin boundaries on the spectroscopic performance of CdZnTe detectors [J].
Parker, BH ;
Stahle, CM ;
Roth, D ;
Babu, S ;
Tueller, J .
HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS III, 2001, 4507 :68-78
[10]   Correlation between bulk material defects and spectroscopic response in cadmium zinc telluride detectors [J].
Parker, BH ;
Stahle, CM ;
Barthelmy, SD ;
Parsons, AM ;
Tueller, J ;
Van Sant, JT ;
Munoz, BF ;
Snodgrass, SJ ;
Mullinix, RE .
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 :129-137