Dynamic reversibility of hydrodynamic focusing for recycling sheath fluid

被引:28
作者
Hashemi, Nastaran [1 ]
Howell, Peter B., Jr. [1 ]
Erickson, Jeffrey S. [1 ]
Golden, Joel P. [1 ]
Ligler, Frances S. [1 ]
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC USA
关键词
MIXER;
D O I
10.1039/c004696e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The phenomenon of "unmixing" has been demonstrated in microfluidic mixers, but here we manipulate laminar flow streams back to their original positions in order to extend the operational utility of an analytical device where no mixing is desired. Using grooves in the channel wall, we passively focus a sample stream with two sheath streams to center it in a microchannel for optical analysis. Even though the sample stream is completely surrounded by sheath fluid, reversing the orientation of the grooves in the channel walls returns the sample stream to its original position with respect to the sheath streams. We demonstrate the separation of the sample stream from the contiguous sheath streams and the recycling of the sheath fluid using the reversibility of laminar flow. Polystyrene microspheres and fluorescent dye were used to quantify the performance of the unsheathing process. We found that the maximum numbers of microspheres and all of the fluorescent dye were recaptured at sheath recycling levels <92%. The use of this sheathing technique has previously been demonstrated in a sensitive microflow cytometer; the unsheathing capability now provides the opportunity to recover particles from the sensor with minimal dilution or to recycle the sheath fluid for long-term unattended operation.
引用
收藏
页码:1952 / 1959
页数:8
相关论文
共 25 条
[1]   Irreversibility and self-organization in hydrodynamic echo experiments [J].
Duering, Gustavo ;
Bartolo, Denis ;
Kurchan, Jorge .
PHYSICAL REVIEW E, 2009, 79 (03)
[2]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[3]   Coding/decoding and reversibility of droplet trains in microfluidic networks [J].
Fuerstman, Michael J. ;
Garstecki, Piotr ;
Whitesides, George M. .
SCIENCE, 2007, 315 (5813) :828-832
[4]   Multi-wavelength microflow cytometer using groove-generated sheath flow [J].
Golden, Joel P. ;
Kim, Jason S. ;
Erickson, Jeffrey S. ;
Hilliard, Lisa R. ;
Howell, Peter B. ;
Anderson, George P. ;
Nasir, Mansoor ;
Ligler, Frances S. .
LAB ON A CHIP, 2009, 9 (13) :1942-1950
[5]  
Hansen C, 2007, PHYS WORLD, V20, P24
[6]   The dissipated power in atomic force microscopy due to interactions with a capillary fluid layer [J].
Hashemi, N. ;
Paul, M. R. ;
Dankowicz, H. ;
Lee, M. ;
Jhe, W. .
JOURNAL OF APPLIED PHYSICS, 2008, 104 (06)
[7]  
Heller J.P., 1960, Am. J. Phys, V28, P348, DOI [10.1119/1.1935802, DOI 10.1119/1.1935802]
[8]   A microfluidic mixer with grooves placed on the top and bottom of the channel [J].
Howell, PB ;
Mott, DR ;
Fertig, S ;
Kaplan, CR ;
Golden, JP ;
Oran, ES ;
Ligler, FS .
LAB ON A CHIP, 2005, 5 (05) :524-530
[9]   Two simple and rugged designs for creating microfluidic sheath flow [J].
Howell, Peter B., Jr. ;
Golden, Joel P. ;
Hilliard, Lisa R. ;
Erickson, Jeffrey S. ;
Mott, David R. ;
Ligler, Frances S. .
LAB ON A CHIP, 2008, 8 (07) :1097-1103
[10]   A combinatorial approach to microfluidic mixing [J].
Howell, Peter B., Jr. ;
Mott, David R. ;
Ligler, Frances S. ;
Golden, Joel P. ;
Kaplan, Carolyn R. ;
Oran, Elaine S. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (11)