A reconstruction algorithm for breast cancer imaging with electrical impedance tomography in mammography geometry

被引:60
作者
Choi, Myoung Hwan
Kao, Tzu-Jen
Isaacson, David
Saulnier, Gary J.
Newell, Jonathan C.
机构
[1] Kangwon NAtl Univ, Dept Elect & Elect Engn, Chunchon, Kangwondo, South Korea
[2] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
[3] Rensselaer Polytech Inst, Dept Math Sci, Troy, NY 12180 USA
[4] Rensselaer Polytech Inst, Dept Elect Comp & Syst Engn, Troy, NY 12180 USA
关键词
breast imaging; electrical impedance tomography; mammography geometry; reconstruction algorithm;
D O I
10.1109/TBME.2006.890139
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system.
引用
收藏
页码:700 / 710
页数:11
相关论文
共 32 条
[1]  
[Anonymous], 1993, CLIN PHYSL APPL ELEC
[2]   The T-SCAN™ technology:: electrical impedance as a diagnostic tool for breast cancer detection [J].
Assenheimer, M ;
Laver-Moskovitz, O ;
Malonek, D ;
Manor, D ;
Nahaliel, U ;
Nitzan, R ;
Saad, A .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :1-8
[3]   Real-time three-dimensional electrical impedance imaging [J].
Blue, RS ;
Isaacson, D ;
Newell, JC .
PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) :15-26
[4]  
BROWN BH, 1992, P ANN INT C IEEE EMB, V5, P1710
[5]  
BROWN BH, 1987, CLIN PHYS PHYSL MEAS, V8
[6]  
Cheney M, 1990, Int J Imaging Syst Technol, V2, P66, DOI 10.1002/ima.1850020203
[7]   ELECTRODE MODELS FOR ELECTRIC-CURRENT COMPUTED-TOMOGRAPHY [J].
CHENG, KS ;
ISAACSON, D ;
NEWELL, JC ;
GISSER, DG .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (09) :918-924
[8]   A 3D electrical impedance tomography (EIT) system for breast cancer detection [J].
Cherepenin, V ;
Karpov, A ;
Korjenevsky, A ;
Kornienko, V ;
Mazaletskaya, A ;
Mazourov, D ;
Meister, D .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (01) :9-18
[9]   ACT3 - A HIGH-SPEED, HIGH-PRECISION ELECTRICAL-IMPEDANCE TOMOGRAPH [J].
COOK, RD ;
SAULNIER, GJ ;
GISSER, DG ;
GOBLE, JC ;
NEWELL, JC ;
ISAACSON, D .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (08) :713-722
[10]   Classification of breast tissue by electrical impedance spectroscopy [J].
da Silva, JE ;
de Sá, JPM ;
Jossinet, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (01) :26-30