PTT Variability for Discrimination of Sleep Apnea Related Decreases in the Amplitude Fluctuations of PPG Signal in Children

被引:62
作者
Gil, Eduardo [1 ,2 ]
Bailon, Raquel [1 ,2 ]
Maria Vergara, Jose [2 ,3 ]
Laguna, Pablo [1 ,2 ]
机构
[1] Univ Zaragoza, Aragon Inst Engn Res, Commun Technol Grp, Zaragoza 50018, Spain
[2] Univ Zaragoza, CIBER BBN, Zaragoza 50018, Spain
[3] Univ Zaragoza, Sleep Dept, Miguel Servet Children Hosp, Zaragoza 50018, Spain
关键词
Children; decreases in the amplitude fluctuations of pulse photoplethysmography signal (PPG) (DAP); PPG; pulse transit time variability (PTTV); sleep apnea; time-frequency; PULSE TRANSIT-TIME; UPPER AIRWAY-OBSTRUCTION; RESPIRATORY EVENTS; PERIPHERAL VASOCONSTRICTION; INSPIRATORY EFFORT; AROUSAL; MANAGEMENT; SYMPTOMS; PRESSURE; OXIMETRY;
D O I
10.1109/TBME.2009.2037734
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inthis paper, an analysis of pulse transit time variability (PTTV) during decreases in the amplitude fluctuations of pulse photoplethysmography signal (PPG) (DAP) events for obstructive sleep apnea syndrome (OSAS) screening is presented. The temporal evolution of time -frequency PTTVparameters duringDAPwas analyzed. The results show an increase in the sympathetic activity index low-frequency component (LF) duringDAP for PTTV (85%) significantly higher than for heart rate variability (HRV) (33%), (p < 10(-13)). However, decreases in parasympathetic activity produce lower decrements in high-frequency component (HF) indexes for PTTV (18%) than for HRV (22%). Thus, PTTV reflects sympathetic changes more clearly than HRV. A clinical study was carried out. DAP events were classified as apneic or nonapneic using a linear discriminant analysis from the PTTV indexes. The ratio of DAP events per hour r(DAP), the ratio after filtering based on HRV indexes r(DAP)(HAV), or on PTTV indexes r(DAP)(PTTV), were computed. The results show an accuracy of 75% for r(DAP)(PTTV) (14% increase with respect to rDAP and 5% increase with respect to r(DAP)(HRV)), a sensitivity of 81.8%, and a specificity of 73.9% when classifying 1-h polysomnographic excerpts as OSAS or normal. These results suggest that the combination of DAP and PTTV could be better alternative for sleep apnea screening using PPG with the added benefit of its low cost and simplicity.
引用
收藏
页码:1079 / 1088
页数:10
相关论文
共 51 条
[31]  
MENDELSON Y, 1992, CLIN CHEM, V38, P1601
[32]   On arousal from sleep: time-frequency analysis [J].
Mendez, M. O. ;
Bianchi, A. M. ;
Montano, N. ;
Patruno, V. ;
Gil, E. ;
Mantaras, C. ;
Aiolfi, S. ;
Cerutti, S. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (04) :341-351
[33]   Pulse transit time by r-wave-gated infrared photoplethysmography: Review of the literature and personal experience [J].
Naschitz J.E. ;
Bezobchuk S. ;
Mussafia-Priselac R. ;
Sundick S. ;
Dreyfuss D. ;
Khorshidi I. ;
Karidis A. ;
Manor H. ;
Nagar M. ;
Peck E.R. ;
Peck S. ;
Storch S. ;
Rosner I. ;
Gaitini L. .
Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) :333-342
[34]   Association of sleep-disordered breathing, sleep apnea, and hypertension in a large community-based study [J].
Nieto, FJ ;
Young, TB ;
Lind, BK ;
Shahar, E ;
Samet, JM ;
Redline, S ;
D'Agostino, RB ;
Newman, AB ;
Lebowitz, MD ;
Pickering, TG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (14) :1829-1836
[35]   The variability of the photoplethysmographic signal - a potential method for the evaluation of the autonomic nervous system [J].
Nitzan, M ;
Babchenko, A ;
Khanokh, B ;
Landau, D .
PHYSIOLOGICAL MEASUREMENT, 1998, 19 (01) :93-102
[36]  
Nixon Gillian M, 2002, Paediatr Respir Rev, V3, P18, DOI 10.1053/prrv.2002.0176
[37]  
Norman RG, 2000, SLEEP, V23, P901
[38]   The effect of upper airway obstruction and arousal on peripheral arterial tonometry, in obstructive sleep apnea [J].
O'Donnell, CP ;
Allan, L ;
Atkinson, P ;
Schwartz, AR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (07) :965-971
[39]   Pulse transit time as a measure of inspiratory effort in children [J].
Pagani, J ;
Villa, MP ;
Calcagnini, G ;
Alterio, A ;
Ambrosio, R ;
Censi, F ;
Ronchetti, R .
CHEST, 2003, 124 (04) :1487-1493
[40]   Systematic comparison of different algorithms for apnoea detection based on electrocardiogram recordings [J].
Penzel, T ;
McNames, J ;
de Chazal, P ;
Raymond, B ;
Murray, A ;
Moody, G .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (04) :402-407