Clinical mammography at the SYRMEP beam line: Toward the digital detection system

被引:17
作者
Dreossi, D. [1 ]
Bergamaschi, A.
Schmitt, B.
Vallazza, E.
Arfelli, F.
Longo, R.
Menk, R. H.
Rigon, L.
Rokvic, T.
Venanzi, C.
Castelli, E.
机构
[1] Univ Trieste, Dept Phys, Trieste, Italy
[2] Ist Nazl Fis Nucl, Trieste, Italy
[3] Paul Scherrer Inst, Villigen, Switzerland
[4] Sincrotrone Trieste SCpA, Trieste, Italy
[5] Univ Belgrade, Fac Phys, Belgrade, Serbia
[6] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
关键词
clinical mammography; synchrotron radiation; digital detector; phase contrast;
D O I
10.1016/j.nima.2007.01.145
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
From the very beginning, the Synchrotron Radiation (SR) for Medical Physics (SYRMEP) collaboration has studied possibilities of improving image quality in mammography, by optimizing source and detector devices. Preliminary studies on test objects and "in vitro" breast tissue samples have been carried out at. a dedicated bending magnet beam line built at the ELETTRA SR facility. Exploiting the characteristics of SIR beams, it has been possible to investigate several phase-sensitive imaging techniques. After the approval of the concerned authorities, clinical examinations have been started with encouraging results. In a first step, screen film systems are used as detection device, but the use of digital detectors is presently under investigation. As custom solution, silicon microstrip sensors of 50 mu m pitch, designed by INFN Trieste and manufactured by Hamamatsu, have been directly bonded to the Mythen single-photon counting read out electronics developed at the Swiss Light Source for SR diffraction experiments. The new version of the read-out ASIC has been tested at the SYRMEP beam line and proved to be able to operate with low noise and high counting rates also for imaging applications, where the cross-talk between the channels is extremely critical. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 163
页数:4
相关论文
共 16 条
[1]   Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA [J].
Abrami, A ;
Arfelli, F ;
Barroso, RC ;
Bergamaschi, A ;
Billé, F ;
Bregant, P ;
Brizzi, F ;
Casarin, K ;
Castelli, E ;
Chenda, V ;
Palma, LD ;
Dreossi, D ;
Fava, A ;
Longo, R ;
Mancini, L ;
Menk, RH ;
Montanari, F ;
Olivo, A ;
Pani, S ;
Pillon, A ;
Quai, E ;
Kaiser, SR ;
Rigon, L ;
Rokvic, T ;
Tonutti, M ;
Tromba, G ;
Vaseotto, A ;
Venanzi, C ;
Zanconati, F ;
Zanetti, A ;
Zanini, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2) :221-227
[2]  
American College of Radiology, 2003, ILL BREAST IM REP DA
[3]   Low-dose phase contrast x-ray medical imaging [J].
Arfelli, F ;
Assante, M ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2845-2852
[4]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[5]   SYRMEP front-end and read-out electronics [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Cristaudo, P ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tomasini, F ;
Tromba, G ;
Vacchi, A ;
Vallazza, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :351-353
[6]   SILICON DETECTORS FOR SYNCHROTRON-RADIATION DIGITAL MAMMOGRAPHY [J].
ARFELLI, F ;
BARBIELLINI, G ;
CANTATORE, G ;
CASTELLI, E ;
DALLAPALMA, L ;
DIMICHIEL, M ;
LONGO, R ;
POROPAT, P ;
ROSEI, R ;
SESSA, M ;
TROMBA, G ;
VACCHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 360 (1-2) :283-286
[7]   At the frontiers of digital mammography: SYRMEP [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :529-533
[8]  
Arfelli F, 2007, AIP CONF PROC, V879, P1895
[9]   Edge on silicon microstrip detectors for medical imaging [J].
Bergamaschi, A ;
Arfelli, F ;
Dreossi, D ;
Longo, R ;
Olivo, A ;
Pani, S ;
Rigon, L ;
Castelli, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 549 (1-3) :199-204
[10]   High-speed single photon counting read out electronics for a digital detection system for clinical synchrotron radiation mammography [J].
Bergamaschi, A ;
Arfelli, F ;
Dreossi, D ;
Longo, R ;
Olivo, A ;
Pani, S ;
Rigon, L ;
Vallazza, E ;
Venanzi, C ;
Castelli, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) :415-417