Use of a quadrupole linear ion trap mass spectrometer in metabolite identification and bioanalysis

被引:98
作者
Xia, YQ
Miller, JD
Bakhtiar, R
Franklin, RB
Liu, DQ
机构
[1] Merck Res Labs, Dept Drug Metab, Rahway, NJ 07065 USA
[2] LC MS Prod Applicat Lab, Framingham, MA 01701 USA
关键词
D O I
10.1002/rcm.1037
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new type of quadrupole linear ion trap mass spectrometer, Q TRAp(TM) LC/MS/MS system (Q TRAP(TM)), was evaluated for its performance in two studies: firstly, the in vitro metabolism of gemfibrozil in human liver microsomes, and, secondly, the quantification of propranolol in rat plasma. With the built-in information-dependent-acquisition (IDA) software, the instrument utilizes full scan MS in the ion trap mode and/or constant neutral loss scans as survey scans to trigger product ion scan (MS2) and MS3 experiments to obtain structural information of drug metabolites 'on-the-fly'. Using this approach, five metabolites of gemfibrozil were detected in a single injection. This instrument combines some of the unique features of a triple quadrupole mass spectrometer, such as constant neutral loss scan, precursor ion scan and multiple reaction monitoring (MRM), together with the capability of a three-dimensional ion trap. Therefore, it becomes a powerful instrument for metabolite identification. The fast duty cycle in the ion trap mode allows the use of full product ion scan for quantification. For the quantification of propranolol, both MRM mode and full product ion scan in the ion trap mode were employed. Similar sensitivity, reproducibility and linearity values were established using these two approaches. The use of the product ion scan mode for quantification provided a convenient tool in selecting transitions for improving selectivity during the method development stage. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:1137 / 1145
页数:9
相关论文
共 26 条
[1]  
Campbell JM, 1998, RAPID COMMUN MASS SP, V12, P1463, DOI 10.1002/(SICI)1097-0231(19981030)12:20<1463::AID-RCM357>3.3.CO
[2]  
2-8
[3]   An interface with a linear quadrupole ion guide for an electrospray-ion trap mass spectrometer system [J].
Cha, BC ;
Blades, M ;
Douglas, DJ .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5647-5654
[4]   Systematic LC/MS metabolite identification in drug discovery [J].
Clarke, N ;
Rindgen, D ;
Korfmacher, W ;
Cox, K .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :430A-439A
[5]   A combined linear ion trap time-of-flight system with improved performance and MSn capabilities [J].
Collings, BA ;
Campbell, JM ;
Mao, DM ;
Douglas, DJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (19) :1777-1795
[6]   Characterization of an electrospray ionization ion trap linear time-of-flight mass spectrometer for phenylthiohydantoin amino acid analysis [J].
Gabryelski, W ;
Purves, RW ;
Li, L .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1998, 176 (03) :213-225
[7]   A new linear ion trap mass spectrometer [J].
Hager, JW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) :512-526
[8]   Use of a liquid chromatography/ion trap mass spectrometry/triple quadrupole mass spectrometry system for metabolite identification [J].
Liu, DQ ;
Xia, YQ ;
Bakhtiar, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (13) :1330-1336
[9]   Comparison in patients with type 2 diabetes of fibric acid versus hepatic hydroxymethyl glutaryl- coenzyme a reductase inhibitor treatment of combined dyslipidemia [J].
McLaughlin, T ;
Abbasi, F ;
Lamendola, C ;
Leary, E ;
Reaven, GM .
METABOLISM-CLINICAL AND EXPERIMENTAL, 2002, 51 (10) :1355-1359
[10]   Mass spectrometry innovations in drug discovery and development [J].
Papac, DI ;
Shahrokh, Z .
PHARMACEUTICAL RESEARCH, 2001, 18 (02) :131-145