Accurate measures of left ventricular ejection fraction using electron beam tomography: A comparison with radionuclide angiography, and cine angiography

被引:16
作者
Baik, HK
Budoff, MJ
Lane, KL
Bakhsheshi, H
Brundage, BH
机构
[1] Harbor UCLA Med Ctr, Torrance, CA 90502 USA
[2] St Johns Cardiovasc Res Ctr, Torrance, CA USA
来源
INTERNATIONAL JOURNAL OF CARDIAC IMAGING | 2000年 / 16卷 / 05期
关键词
catheterization angiography; cine angiography; ejection fraction; electron beam tomography; electron beam computed tomography; radionuclide angiography;
D O I
10.1023/A:1026536510821
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Quantitative determination of ejection fraction is predicated on precise measurement of end-diastolic and end-systolic volumes of the left ventricle. Contrast enhanced electron beam tomography (EBT), with excellent temporal and spatial resolution, has the potential for highly accurate measures of ejection fraction. Methods: EBT protocol used a short axis scan of the left ventricle (8-12 levels, apex to base) during infusion of iodinated contrast. To assess the accuracy of the measured left ventricular ejection fraction (LVEF), we compared EBT with first-pass radionuclide angiography (RNA) and cine angiography (CINE). Results: A total of 41 patients (26 men and 15 women) underwent all three tests within 1 week. Resting ejection fraction using each modality was assessed in a linear regression model to assess inter-test correlation with the other two modalities. Correlation between CINE and EBT was high (r = 0.90, intercept 4.67, p < 0.001). Similarly, correlation of CINE and RNA (r = 0.87, intercept -5.48, p < 0.001) and between EBT and RNA (r = 0.87, intercept -4.6, p < 0.001) were high. In a subset of those patients with LVEF less than or equal to 40%, correlation was consistently high between EBT and CINE. However, correlations were poor for the comparisons between RNA and CINE (r = 0.40), and between the RNA and EBT (r = 0.47). The mean differences of measured ejection fractions between each of the imaging modality were small. However, there was only modest agreement between each of the comparisons as measured using 95% confidence interval (CI) on Bland-Altman plots. Conclusion: These data indicate that the LVEF results are comparable among EBT, RNA, and CINE and can be used interchangeably to assess ventricular function for LVEF > 40%. For LVEF less than or equal to 40%, we demonstrated some disparate results between cine angiography and RNA and between EBT and RNA, indicating that CINE or EBT may provide more accurate assessment.
引用
收藏
页码:391 / 398
页数:8
相关论文
共 26 条
[21]   DETERMINATION OF LEFT-VENTRICULAR EJECTION FRACTION USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
RICH, S ;
CHOMKA, EV ;
STAGL, R ;
SHANES, JG ;
KONDOS, GT ;
BRUNDAGE, BH .
AMERICAN HEART JOURNAL, 1986, 112 (02) :392-396
[22]   EXERCISE ULTRAFAST COMPUTED-TOMOGRAPHY FOR THE DETECTION OF CORONARY-ARTERY DISEASE [J].
ROIG, E ;
CHOMKA, EV ;
CASTANER, A ;
CAMPO, A ;
HERAS, M ;
RICH, S ;
BRUNDAGE, BH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (05) :1073-1081
[23]   Determination of ventricular ejection fraction: A comparison of available imaging methods [J].
Rumberger, JA ;
Behrenbeck, T ;
Bell, MR ;
Breen, JF ;
Johnston, DL ;
Holmes, DR ;
EnriquezSarano, M .
MAYO CLINIC PROCEEDINGS, 1997, 72 (09) :860-870
[24]   COMPARISON OF RADIONUCLIDE VENTRICULOGRAPHY AND 2D ECHOCARDIOGRAPHY FOR THE MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION FOLLOWING ACUTE MYOCARDIAL-INFARCTION [J].
SENIOR, R ;
SRIDHARA, BS ;
BASU, S ;
HENLEY, M ;
HANDLER, CE ;
RAFTERY, EB ;
LAHIRI, A .
EUROPEAN HEART JOURNAL, 1994, 15 (09) :1235-1239
[25]  
THOMPSON BH, 1994, RADIOL CLIN N AM, V32, P537
[26]  
Wolfkiel C J, 1986, Am J Physiol Imaging, V1, P117