摘要
Background: Quantitative determination of ejection fraction is predicated on precise measurement of end-diastolic and end-systolic volumes of the left ventricle. Contrast enhanced electron beam tomography (EBT), with excellent temporal and spatial resolution, has the potential for highly accurate measures of ejection fraction. Methods: EBT protocol used a short axis scan of the left ventricle (8-12 levels, apex to base) during infusion of iodinated contrast. To assess the accuracy of the measured left ventricular ejection fraction (LVEF), we compared EBT with first-pass radionuclide angiography (RNA) and cine angiography (CINE). Results: A total of 41 patients (26 men and 15 women) underwent all three tests within 1 week. Resting ejection fraction using each modality was assessed in a linear regression model to assess inter-test correlation with the other two modalities. Correlation between CINE and EBT was high (r = 0.90, intercept 4.67, p < 0.001). Similarly, correlation of CINE and RNA (r = 0.87, intercept -5.48, p < 0.001) and between EBT and RNA (r = 0.87, intercept -4.6, p < 0.001) were high. In a subset of those patients with LVEF less than or equal to 40%, correlation was consistently high between EBT and CINE. However, correlations were poor for the comparisons between RNA and CINE (r = 0.40), and between the RNA and EBT (r = 0.47). The mean differences of measured ejection fractions between each of the imaging modality were small. However, there was only modest agreement between each of the comparisons as measured using 95% confidence interval (CI) on Bland-Altman plots. Conclusion: These data indicate that the LVEF results are comparable among EBT, RNA, and CINE and can be used interchangeably to assess ventricular function for LVEF > 40%. For LVEF less than or equal to 40%, we demonstrated some disparate results between cine angiography and RNA and between EBT and RNA, indicating that CINE or EBT may provide more accurate assessment.
引用
收藏
页码:391 / 398
页数:8
相关论文
共 26 条
[11]   Assessment of left ventricular function: Comparison between radionuclide angiography and semiquantitative two-dimensional echocardiographic analysis [J].
GottsaunerWolf, M ;
SchedlmayerDuit, J ;
Porenta, G ;
Gwechenberger, M ;
Huber, K ;
Glogar, D ;
Probst, P ;
Sochor, H .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (12) :1613-1618
[12]   VARIABLES PREDICTIVE OF SURVIVAL IN PATIENTS WITH CORONARY-DISEASE - SELECTION BY UNIVARIATE AND MULTIVARIATE ANALYSES FROM THE CLINICAL, ELECTROCARDIOGRAPHIC, EXERCISE, ARTERIOGRAPHIC, AND QUANTITATIVE ANGIOGRAPHIC EVALUATIONS [J].
HAMMERMEISTER, KE ;
DEROUEN, TA ;
DODGE, HT .
CIRCULATION, 1979, 59 (03) :421-430
[13]   SOURCES OF VARIABILITY IN THE RADIONUCLIDE ANGIOGRAPHIC ASSESSMENT OF EJECTION FRACTION - A COMPARISON OF 1ST-PASS AND GATED EQUILIBRIUM TECHNIQUES [J].
KAUL, S ;
BOUCHER, CA ;
OKADA, RD ;
NEWELL, JB ;
STRAUSS, HW ;
POHOST, GM .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (06) :823-828
[14]   DETERMINANTS OF LEFT-VENTRICULAR EJECTION FRACTION BY ULTRAFAST COMPUTED-TOMOGRAPHY [J].
MACMILLAN, RM ;
REES, MR .
ANGIOLOGY, 1988, 39 (03) :203-210
[15]   COMPARISON OF LEFT-VENTRICULAR EJECTION FRACTION BY CINE COMPUTED-TOMOGRAPHY AND SINGLE PLANE RIGHT ANTERIOR OBLIQUE VENTRICULOGRAPHY [J].
MACMILLAN, RM ;
REES, MR ;
MARANHAO, V ;
CLARK, DL .
ANGIOLOGY, 1986, 37 (04) :299-305
[16]   ASSESSMENT OF GLOBAL AND REGIONAL LEFT-VENTRICULAR FUNCTION IN ISCHEMIC HEART-DISEASE USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
MACMILLAN, RM ;
REES, MR ;
WEINER, R ;
MARANHAO, V .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 14 (04) :248-254
[17]   ULTRAFAST COMPUTED-TOMOGRAPHY IN THE DIAGNOSIS OF CARDIAC DISEASE [J].
MARCUS, ML ;
STANFORD, W ;
HAJDUCZOK, ZD ;
WEISS, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (09) :E54-E59
[18]   PATTERNS OF GLOBAL AND REGIONAL SYSTOLIC AND DIASTOLIC FUNCTION IN THE NORMAL RIGHT VENTRICLE ASSESSED BY ULTRAFAST COMPUTED-TOMOGRAPHY [J].
MARZULLO, P ;
LABBATE, A ;
MARCUS, ML .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (06) :1318-1325
[19]   VALIDATION OF ULTRAFAST COMPUTED TOMOGRAPHIC LEFT-VENTRICULAR VOLUME MEASUREMENT [J].
PIETRAS, RJ ;
WOLFKIEL, CJ ;
VESELIK, K ;
ROIG, E ;
CHOMKA, EV ;
BRUNDAGE, BH .
INVESTIGATIVE RADIOLOGY, 1991, 26 (01) :28-34
[20]   PRECISION OF MEASUREMENTS OF RIGHT AND LEFT-VENTRICULAR VOLUME BY CINE COMPUTED-TOMOGRAPHY [J].
REITER, SJ ;
RUMBERGER, JA ;
FEIRING, AJ ;
STANFORD, W ;
MARCUS, ML .
CIRCULATION, 1986, 74 (04) :890-900