Development of a semi-automatic alignment tool for accelerated localization of the prostate

被引:37
作者
Hua, CH
Lovelock, DM
Mageras, GS
Katz, MS
Mechalakos, J
Lief, EP
Hollister, T
Lutz, WR
Zelefsky, MJ
Ling, CC
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Phys Med, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10021 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 03期
关键词
prostate cancer; external beam radiation therapy; prostate targeting; computed tomography;
D O I
10.1016/S0360-3016(02)04207-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Delivering high dose to prostate with external beam radiation has been shown to improve local tumor control. However, it has to be carefully performed to avoid partial target miss and delivering excessive dose to surrounding normal tissues. One way to achieve safe dose escalation is to precisely localize prostate immediately before daily treatment. Therefore, the radiation can be accurately delivered to the target. Once the prostate position is determined with high confidence, planning target volume (PTV) safety margin might be reduced for further reduction of rectal toxicity. A rapid computed tomography (CT)-based online prostate localization method is presented for this purpose. Methods and Materials: Immediately before each treatment session, the patient is immobilized and undergoes a CT scan in the treatment position using a CT scanner situated in the treatment room. At the CT console, posterior, anterior, left, and right extents of the prostate are manually identified on each axial slice. The translational prostate displacements relative to the planned position are estimated by simultaneously fitting these identified extents from this CT scan to a template created from the finely sliced planning CT scan. A total of 106 serial CT scans from 8 prostate cancer patients were performed immediately before treatments and used to retrospectively evaluate the precision of this daily prostate targeting method. The three-dimensional displacement of the prostate with respect to its planned position was estimated. Results: Five axial slices from each treatment CT scan were sufficient to produce a reliable correction when compared with prostate center of gravity (CoG) displacements calculated from physician-drawn contours. The differences (mean +/- SD) between these two correction schemes in the right-left (R/L), posterior-anterior (P/A), and superior-inferior (S/I) directions are 0.0 +/- 0.4 mm, 0.0 +/- 0.7 mm, and -0.4 +/- 1.9 mm, respectively. With daily CT extent-fitting correction, 97% of the scans showed that the entire posterior prostate gland was covered by PTV given a margin of 6 mm at the rectum-prostate interface and 10 mm elsewhere. In comparison, only 74% and 65% could be achieved by the corrections based on daily and weekly bony matching on portal images, respectively. Conclusions: Results show that daily CT extent fitting provides a precise correction of prostate position in terms of CoG. Identifying prostate extents on five axial CT slices at the CT console is less time-consuming compared with daily contouring of the prostate on many slices. Taking advantage of the prostate curvature in the longitudinal direction, this method also eliminates the necessity of identifying prostate base and apex. Therefore, it is clinically feasible and should provide an accelerated localization of the prostate immediately before daily treatment. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:811 / 824
页数:14
相关论文
共 37 条
  • [1] Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility
    Balter, JM
    Lam, KL
    Sandler, HM
    Littles, JF
    Bree, RL
    TenHaken, RK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1281 - 1286
  • [2] Analysis of prostate and seminal vesicle motion: Implications for treatment planning
    Beard, CJ
    Kijewski, P
    Bussiere, M
    Gelman, R
    Gladstone, D
    Shaffer, K
    Plunkett, M
    Costello, P
    Coleman, CN
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02): : 451 - 458
  • [3] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [4] High-precision conformal radiotherapy (HPCRT) of prostate cancer -: A new technique for exact positioning of the prostate at the time of treatment
    Bergström, P
    Löfroth, PO
    Widmark, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02): : 305 - 311
  • [5] Dose escalation with 3D conformal treatment: Five year outcomes, treatment optimization, and future directions
    Hanks, GE
    Hanlon, AL
    Schultheiss, TE
    Pinover, WH
    Movsas, B
    Epstein, BE
    Hunt, MA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03): : 501 - 510
  • [6] A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets
    Jaffray, DA
    Drake, DG
    Moreau, M
    Martinez, AA
    Wong, JW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03): : 773 - 789
  • [7] Daily CT localization for correcting portal errors in the treatment of prostate cancer
    Lattanzi, J
    McNeely, S
    Hanlon, A
    Das, I
    Schultheiss, TE
    Hanks, GE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (05): : 1079 - 1086
  • [8] Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer
    Lattanzi, J
    McNeeley, S
    Hanlon, A
    Schultheiss, TE
    Hanks, GE
    [J]. UROLOGY, 2000, 55 (01) : 73 - 78
  • [9] Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation
    Ling, CC
    Burman, C
    Chui, CS
    Kutcher, GJ
    Leibel, SA
    LoSasso, T
    Mohan, R
    Bortfeld, T
    Reinstein, L
    Spirou, S
    Wang, XH
    Wu, QW
    Zelefsky, M
    Fuks, Z
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04): : 721 - 730
  • [10] TOMOTHERAPY - OPTIMIZED PLANNING AND DELIVERY OF RADIATION-THERAPY
    MACKIE, TR
    HOLMES, TW
    RECKWERDT, PJ
    YANG, J
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1995, 6 (01) : 43 - 55