Flow injection on-line two-stage solvent extraction preconcentration coupled with ET-AAS for determination of bismuth tn biological and environmental samples

被引:38
作者
Wang, JH [1 ]
Hansen, EH [1 ]
机构
[1] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
关键词
FIA/SIA on-line two stage solvent extraction; electrothermal atomic absorption spectrometry; river sediment; human urine; bismuth;
D O I
10.1080/00032710008543220
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust flow injection/sequential injection(FIA/SIA) on-line two-stage solvent extraction separation/preconcentration procedure coupled to electrothermal atomic absorption spectiometry (ETAAS) is described and demonstrated for the determination of trace-levels of bismuth. In 1-4% (v/v) nitric acid medium, diethyldithiophosphate (DDPA) chelates bismuth and the chelating complex formed is extracted into isobutyl methyl ketone (IBMK), which is separated from the aqueous phase by means of cavity gravitational phase separation. Both single and two-stage separations are used. In each case, 40 mu l of the concentrate is entrapped and metered in a loop, and subsequently delivered via air-segmentation into a pyrolytically coated graphite tube. The ETAAS determination is performed in parallel with the preconcentration process of the ensuing sample. Enrichment factors of 17.8 and 31.5, detection limits of 12 ng l(-1) and 10.5 ng l(-1) for single and two-stage extractions, respectively, along with a sampling frequency of 13 h(-1) were obtained with 100 s of sample loading time at a sample flow rate of 5.4 mi min(-1). The relative standard deviations were 2.8% and 1.9% for single and two-stage extractions, respectively. The procedure was validated by determining the bismuth content in a certified reference material and in human urine samples.
引用
收藏
页码:2747 / 2766
页数:20
相关论文
共 17 条
[1]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[2]   PRECONCENTRATION AND MATRIX-ISOLATION OF HEAVY-METALS THROUGH A 2-STAGE SOLVENT-EXTRACTION IN A FLOW SYSTEM [J].
BENGTSSON, M ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1984, 158 (02) :147-156
[3]  
*BOD PERK ELM GMBH, 1995, THGA GRAPH FURN TECH
[4]   THE ASSESSMENT OF REFERENCE VALUES FOR ELEMENTS IN HUMAN BIOLOGICAL TISSUES AND FLUIDS - A SYSTEMATIC REVIEW [J].
CAROLI, S ;
ALIMONTI, A ;
CONI, E ;
PETRUCCI, F ;
SENOFONTE, O ;
VIOLANTE, N .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1994, 24 (5-6) :363-398
[5]   Two-step solvent extraction flow injection system for the determination of anionic surfactants by spectrophotometry [J].
Fan, SH ;
Fang, ZL .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (04) :416-419
[6]  
FROOMES PRA, 1988, CLIN CHEM, V34, P382
[7]   Determination of bismuth in cod muscle, lake and river sediment by flow injection on-line sorption preconcentration in a knotted reactor coupled with electrothermal atomic absorption spectrometry [J].
Ivanova, E ;
Yan, XP ;
Adams, F .
ANALYTICA CHIMICA ACTA, 1997, 354 (1-3) :7-13
[8]  
MARSHALL BJ, 1991, AM J GASTROENTEROL, V86, P16
[9]   Hydride generation graphite furnace atomic absorption determination of bismuth in clinical samples with in situ preconcentration [J].
Matusiewicz, H ;
Kopras, M ;
Suszka, A .
MICROCHEMICAL JOURNAL, 1995, 52 (03) :282-289
[10]   Pre-concentration system for bismuth determination in urine using FI-ICP-AES with ultrasonic nebulization [J].
Moyano, S ;
Gásquez, JA ;
Olsina, R ;
Marchevsky, E ;
Martinez, LD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (02) :259-262