Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand

被引:56
作者
Ellis, B [1 ]
Bruton, A [1 ]
Goddard, JR [1 ]
机构
[1] UNIV SOUTHAMPTON,SOUTHAMPTON GEN HOSP,SOUTHAMPTON SO17 1BJ,HANTS,ENGLAND
关键词
D O I
10.1177/026921559701100408
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: To compare the inter-and intra-rater reliability of goniometry and wire tracing in the assessment of finger joint angles: metacarpo-phalangeal (MCPJ), proximal (PIPJ) and distal interphalangeal joints (DIPJ). Design: Twenty occupational therapists and 20 physiotherapists with a range of clinical experience were recruited from nine different centres. Using a masked goniometer and wire tracing they carried out repealed assessments of the MCPJ, PIPJ and DIPJ of a normal subject fixed in two different positions. Results: The two assessment methods did not produce comparable angle measurements. Goniometry showed greater inter-and intra-rater reliability than wire tracing. Regardless of the assessment tool, the repeatability coefficient indicated that DIPJ measurement was less reliable than the other joints. Clinical and specialist experience did not affect reliability, Conclusion: Although both goniometry and wire tracing show limitations as reliable assessment tools, it is recommended that where possible goniometry should be used.
引用
收藏
页码:314 / 320
页数:7
相关论文
共 38 条
[21]  
NILSSON N, 1995, J MANIP PHYSIOL THER, V18, P293
[22]  
Norkin C. C., 1995, MEASUREMENT JOINT MO
[23]  
REYNOLDS P M G, 1975, Rheumatology and Rehabilitation, V14, P180, DOI 10.1093/rheumatology/14.3.180
[24]   INTERTESTER RELIABILITY AND CONCURRENT VALIDITY OF FLUID-BASED AND UNIVERSAL GONIOMETERS FOR ACTIVE KNEE FLEXION [J].
RHEAULT, W ;
MILLER, M ;
NOTHNAGEL, P ;
STRAESSLE, J ;
URBAN, D .
PHYSICAL THERAPY, 1988, 68 (11) :1676-1678
[25]   HAND ASSESSMENT CHARTS [J].
ROBINS, RHC .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1986, 11B (02) :287-298
[26]   A reliability study of the universal goniometer, fluid goniometer, and electrogoniometer for the measurement of ankle dorsiflexion [J].
Rome, K ;
Cowieson, F .
FOOT & ANKLE INTERNATIONAL, 1996, 17 (01) :28-32
[27]   GONIOMETRIC RELIABILITY IN A CLINICAL SETTING - ELBOW AND KNEE MEASUREMENTS [J].
ROTHSTEIN, JM ;
MILLER, PJ ;
ROETTGER, RF .
PHYSICAL THERAPY, 1983, 63 (10) :1611-1615
[28]  
Salter MI, 1987, HAND INJURIES THERAP, P15
[29]   METHODS OF MEASUREMENT OF MUSCLE AND JOINT FUNCTION [J].
SALTER, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1955, 37 (03) :474-491
[30]  
SOLGAARD S, 1986, SCAND J REHABIL MED, V18, P5