Protonation in electrospray mass spectrometry: Wrong-way-round or right-way-round?

被引:127
作者
Zhou, SL [1 ]
Cook, KD [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
关键词
D O I
10.1016/S1044-0305(00)00174-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The term "wrong-way-round ionization" has been used in studies of electrospray ionization to describe the observation of protonated or deprotonated ions when sampling strongly basic or acidic solutions (respectively) where such ions are not expected to exist in appreciable concentrations in solution. Study of the dependence of ionization of the weak base caffeine on the electrospray capillary potential reveals three distinct contributors to wrong-way-round ionization. At near-neutral pH in solutions of low ionic strength, protonation of caffeine results from the surface enrichment of electrolytically produced protons in the surface layer of the droplets from which ions are desorbed. For solutions made strongly basic with ammonia, gas-phase proton transfer from ammonium ions can create protonated caffeine. These two mechanisms have been discussed previously elsewhere. For solutions of high ionic strength at neutral or high pH, the data suggest that discharge-induced ionization is responsible for the production of protonated caffeine. This mechanism probably accounts for some of the wrong-way-round ionization reported elsewhere. (C) 2000 American Society for Mass Spectrometry.
引用
收藏
页码:961 / 966
页数:6
相关论文
共 33 条
[1]   MASS-SPECTROMETRY WITH ION SOURCES OPERATING AT ATMOSPHERIC-PRESSURE [J].
BRUINS, AP .
MASS SPECTROMETRY REVIEWS, 1991, 10 (01) :53-77
[2]   Differentiating between capillary and counter electrode processes during electrospray ionization by opening the short circuit at the collector [J].
Charbonnier, F ;
Berthelot, L ;
Rolando, C .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1585-1591
[3]  
COOKS RG, 1994, MASS SPECTROM REV, V13, P287
[4]   A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes [J].
Enke, CG .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4885-4893
[5]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[6]   ION FORMATION FROM CHARGED DROPLETS - ROLES OF GEOMETRY, ENERGY, AND TIME [J].
FENN, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :524-535
[7]   ACIDITY DETERMINATION IN DROPLETS FORMED BY ELECTROSPRAYING METHANOL-WATER SOLUTIONS [J].
GATLIN, CL ;
TURECEK, F .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :712-718
[8]   MECHANISM AND RATE CONSTANTS OF ION-MOLECULE RFACTIONS LEADING TO FORMATION OF H+(H2O)N IN MOIST OXYGEN AND AIR [J].
GOOD, A ;
DURDEN, DA ;
KEBARLE, P .
JOURNAL OF CHEMICAL PHYSICS, 1970, 52 (01) :222-&
[9]   ARE THE ELECTROSPRAY MASS-SPECTRA OF PROTEINS RELATED TO THEIR AQUEOUS-SOLUTION CHEMISTRY [J].
GUEVREMONT, R ;
SIU, KWM ;
LEBLANC, JCY ;
BERMAN, SS .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (03) :216-224
[10]  
Harrison A.G., 1992, Chemical Ionization Mass Spectrometry, V2, P91