Indirect fluorescence detection of phenolic compounds by capillary electrophoresis on a glass device

被引:16
作者
Arundell, M
Whalley, PD
Manz, A [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Zeneca Smithkline Beecham Ctr Analyt Sci, London SW7 2AY, England
[2] Water Res Ctr Plc, Marlow SL7 2HD, Bucks, England
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 367卷 / 08期
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会;
关键词
D O I
10.1007/s002160000460
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micromachined capillary electrophoresis system has been fabricated on a glass device for the separation and indirect fluorescence detection of phenols. Using this device two phenols viz., 2,4-dichlorophenol and pentachlorophenol, were separated within 12 s compared to under 19 min on a conventional capillary electrophoresis system using direct ultraviolet detection. The precision of the glass device ranged from 12.7%-16.7% compared to 0.42%-4.9% for the conventional system. Both systems showed good linearity in the concentration range of 0.8-6.38 mM for the glass device and 5-130 mu M for the conventional system. The relationship between temperature and high voltage with baseline drift was also investigated. These results provide a foundation for the development of a miniaturised chemical analysis system for the on-line analysis of phenols in water.
引用
收藏
页码:686 / 691
页数:6
相关论文
共 20 条
[1]   A METHOD FOR THE ANALYSIS OF PHENOL AND MONOCHLORINATED AND BROMINATED PHENOLS FROM COMPLEX AQUEOUS SAMPLES [J].
BOOTH, RA ;
LESTER, JN .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1994, 32 (07) :259-264
[2]  
CHAO CY, 1994, J CHROMATOGR A, V633, P229
[3]  
Cremlyn R J, 1991, AGROCHEMICALS PREPAR
[4]  
HARRIS CC, 1992, PPO UPDATES, V6, P1
[5]   Capillary electrophoretic separation of chlorophenols using amperometric detection [J].
Hilmi, A ;
Luong, JHT ;
Nguyen, AL .
JOURNAL OF CHROMATOGRAPHY A, 1997, 761 (1-2) :259-268
[6]   Microchip structures for submillisecond electrophoresis [J].
Jacobson, SC ;
Culbertson, CT ;
Daler, JE ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (16) :3476-3480
[7]   Capillary zone electrophoresis at subzero temperatures III.: Operating conditions and separation efficiency [J].
Ma, S ;
Horváth, C .
JOURNAL OF CHROMATOGRAPHY A, 1998, 825 (01) :55-69
[8]   MINIATURIZED TOTAL CHEMICAL-ANALYSIS SYSTEMS - A NOVEL CONCEPT FOR CHEMICAL SENSING [J].
MANZ, A ;
GRABER, N ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :244-248
[9]   PLANAR CHIPS TECHNOLOGY FOR MINIATURIZATION AND INTEGRATION OF SEPARATION TECHNIQUES INTO MONITORING SYSTEMS - CAPILLARY ELECTROPHORESIS ON A CHIP [J].
MANZ, A ;
HARRISON, DJ ;
VERPOORTE, EMJ ;
FETTINGER, JC ;
PAULUS, A ;
LUDI, H ;
WIDMER, HM .
JOURNAL OF CHROMATOGRAPHY, 1992, 593 (1-2) :253-258
[10]   Separation of eleven priority phenols by capillary zone electrophoresis with ultraviolet detection [J].
Martinez, D ;
Pocurull, E ;
Marce, RM ;
Borrull, F ;
Calull, M .
JOURNAL OF CHROMATOGRAPHY A, 1996, 734 (02) :367-373