Sensors and biosensors based on clay-modified electrodes - new trends

被引:299
作者
Mousty, C [1 ]
机构
[1] Univ Grenoble 1, Lab Electrochim Organ & Photochim Redox, CNRS,Inst Chim Mol Grenoble, UMR 5630,FR 2607, Grenoble 9, France
关键词
clay-modified electrodes; electroanalysis; electrochemical biosensors; layered double hydroxides; redox mediator; enzyme;
D O I
10.1016/j.clay.2004.06.005
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Clay-modified electrodes (CLMEs) have received attention in the development of electrochemical sensors and biosensors. This article reviews the use of CLME for these electroanalytical purposes. It includes an introduction to the structure of cationic and anionic clays, an overview of electron transfer occurring at CLME, and of the different modes of preparation of CLME. The analytical applications reported for CLME range from the preconcentration method applied to the detection of cationic species (i.e.. metal cations) or organic molecules (i.e., water pollutants and drugs), to electrocatalytic sensors involving intercalated redox mediators in the electrochemical detection process, and finally to amperometric and potentiometric biosensors. Several enzymes have been immobilized within clay matrices and amperometric biosensors based on CLME are presented following the three modes of detection referred to as first, second, and third generation of biosensors, depending on the nature of the enzymes. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:159 / 177
页数:19
相关论文
共 144 条
[91]   Use of a carbon paste modified electrode for the determination of 2-nitrophenol in a flow system by differential pulse voltammetry [J].
Rodriguez, IN ;
Leyva, JAM ;
deCisneros, JLHH .
ANALYTICA CHIMICA ACTA, 1997, 344 (03) :167-173
[92]   ELECTROCHEMISTRY AND PHOTOELECTROCHEMISTRY OF PILLARED-CLAY-MODIFIED ELECTRODES [J].
RONG, DT ;
KIM, YI ;
MALLOUK, TE .
INORGANIC CHEMISTRY, 1990, 29 (08) :1531-1535
[93]   POLYPYRROLE CLAY-MODIFIED ELECTRODES [J].
RUDZINSKI, WE ;
FIGUEROA, C ;
HOPPE, C ;
KUROMOTO, TY ;
ROOT, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 243 (02) :367-378
[94]   Electrochemical behavior of c-type cytochromes at clay-modified carbon electrodes:: a model for the interaction between proteins and soils [J].
Sallez, Y ;
Bianco, P ;
Lojou, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 493 (1-2) :37-49
[95]   Electrochemical characterisation of Ni/Al-X hydrotalcites and their electrocatalytic behaviour [J].
Scavetta, E ;
Berrettoni, M ;
Giorgetti, M ;
Tonelli, D .
ELECTROCHIMICA ACTA, 2002, 47 (15) :2451-2461
[96]  
Scheller Frieder W, 2002, J Biotechnol, V82, P411, DOI 10.1016/S1389-0352(01)00055-1
[97]   A laponite clay-poly(pyrrole-pyridinium) matrix for the fabrication of conductimetric microbiosensors [J].
Senillou, A ;
Jaffrezic, N ;
Martelet, C ;
Cosnier, S .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :117-124
[98]   Layered double hydroxides: An attractive material for electrochemical biosensor design [J].
Shan, D ;
Cosnier, S ;
Mousty, C .
ANALYTICAL CHEMISTRY, 2003, 75 (15) :3872-3879
[99]   Subnanomolar cyanide detection at polyphenol oxidase/clay biosensors [J].
Shan, D ;
Mousty, C ;
Cosnier, S .
ANALYTICAL CHEMISTRY, 2004, 76 (01) :178-183
[100]   HRP/[Zn-Cr-ABTS] redox clay-based biosensor: design and optimization for cyanide detection [J].
Shan, D ;
Cosnier, S ;
Mousty, C .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (02) :390-396