Energy- and intensity-modulated electron beams for radiotherapy

被引:91
作者
Ma, CM [1 ]
Pawlicki, T [1 ]
Lee, MC [1 ]
Jiang, SB [1 ]
Li, JS [1 ]
Deng, J [1 ]
Yi, B [1 ]
Mok, E [1 ]
Boyer, AL [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
D O I
10.1088/0031-9155/45/8/316
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work investigates the feasibility of optimizing energy- and intensity-modulated electron beams for radiation therapy. A multileaf collimator (MLC) specially designed for modulated electron radiotherapy (MERT) was investigated both experimentally and by Monte Carlo simulations: An inverse-planning system based on Monte Carlo dose calculations was developed to optimize electron beam energy and intensity to achieve dose conformity for target volumes near the surface. The results showed that an MLC with 5 mm leaf widths could produce complex held shapes for MERT. Electron intra- and inter-leaf leakage had negligible effects on the dose distributions delivered with the MLC, even at shallow depths. Focused leaf ends reduced the electron scattering contributions to the dose compared with straight leaf ends. As anticipated, moving the MLC position toward the patient surface reduced the penumbra significantly. There were significant differences in the beamlet distributions calculated by an analytic 3-D pencil beam algorithm and the Monte Carlo method. The Monte Carlo calculated beamlet distributions were essential to the accuracy of the MERT dose distribution in cases involving large air gaps, oblique incidence and heterogeneous treatment targets (at the tissue-bone and bone-lung interfaces). To demonstrate the potential of MERT for target dose coverage and normal tissue sparing for treatment of superficial targets, treatment plans For a hypothetical treatment were compared using photon beams and MERT.
引用
收藏
页码:2293 / 2311
页数:19
相关论文
共 58 条
[1]  
[Anonymous], 1983, MED PHYS, V10, P741
[2]   Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation [J].
Asell, M ;
Hyodynmaa, S ;
Gustafsson, A ;
Brahme, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2083-2100
[3]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[4]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[5]  
BIELAJEW AF, 1987, USE COMPUTERS RAD TH, P65
[6]  
BOESECKE R, 1988, STRAHLENTHER ONKOL, V164, P151
[7]   Modulated beam conformal therapy for head and neck tumors [J].
Boyer, AL ;
Geis, P ;
Grant, W ;
Carol, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :227-236
[8]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[9]   Three dimensional conformal treatment planning with multileaf collimators [J].
Brewster, L ;
Mohan, R ;
Mageras, G ;
Burman, C ;
Leibel, S ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1081-1089
[10]   DOSE CALCULATION FOR PHOTON BEAMS WITH INTENSITY MODULATION GENERATED BY DYNAMIC JAW OR MULTILEAF COLLIMATIONS [J].
CHUI, CS ;
LOSASSO, T ;
SPIROU, S .
MEDICAL PHYSICS, 1994, 21 (08) :1237-1244