Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography

被引:36
作者
Hur, Gham [1 ]
Hong, Seong Wan
Kim, Su Young
Kim, Yong Hoon
Hwang, Yoon Joon
Lee, Won Ro
Cha, Soon Joo
机构
[1] Inje Univ, Ilsanpaik Hosp, Dept Radiol, Goyang 411706, Gyuanggi Do, South Korea
[2] Inje Univ, Ilsanpaik Hosp, Dept Cardiol, Goyang 411706, Gyuanggi Do, South Korea
关键词
cardiac imaging; coronary CT angiography; CT technique; radiation dose; tube current modulation;
D O I
10.2214/AJR.06.1201
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to evaluate whether the SD of CT attenuation values obtained from unenhanced scans of the left atrium is a reliable parameter for the individual modulation of tube current to achieve uniform image quality in coronary CT angiography (CTA). MATERIALS AND METHODS. One hundred patients ( 59 men and 41 women) who were suspected to have coronary artery disease underwent coronary CTA using a 64-MDCT scanner. In addition to clinical studies, we also performed measurements on water phantoms. Tube current was modulated by the SD of the CT attenuation values measured from the left atrium on unenhanced images scanned at 300 mA. A modulation table was created from data obtained from the studies of water phantoms scanned at various tube currents. Other scanning parameters were identical to those used to obtain unenhanced and contrast-enhanced studies of the 100 patients. The SD values were measured from images scanned at an adjusted tube current, and the images of normal coronary and internal mammary arteries were graded. Radiation doses measured using the volume CT dose index ( CTDIvol) were compared between the SD of the CT attenuation values and the modulation parameters suggested by the manufacturer of the scanner. RESULTS. Image quality was rated as grade 3 ( low mottle) on a 4-grade scale by four observers for 92 - 94 of the 100 patients ( average, 92.5%). The mean SD value at an adjusted tube current was 12.1 H with an SD of 0.758 H ( target SD = 12 H). A radiation dose reduction of 9 - 45% was achieved in patients grouped by weight who weighed less than 70 kg, and a reduction of up to 71% was seen in individual cases. CONCLUSION. Modulating tube current using the SD of CT attenuation values from the left atrium is a highly reliable method of achieving uniform image quality in coronary CTA.
引用
收藏
页码:188 / 196
页数:9
相关论文
共 33 条
[1]   MDCT of the coronary arteries: Feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose [J].
Abada, Hicham T. ;
Larchez, Christophe ;
Daoud, Beatrice ;
Sigal-Cinqualbre, Anne ;
Paul, Jean-Francois .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S387-S390
[2]   New vessel analysis tool for morphometric quantification and visualization of vessels in CT and MR imaging data sets [J].
Boskamp, T ;
Rinck, D ;
Link, F ;
Kümmerlen, B ;
Stamm, G ;
Mildenberger, P .
RADIOGRAPHICS, 2004, 24 (01) :287-297
[3]  
BROOKS R A, 1976, Medical Physics (Woodbury), V3, P237, DOI 10.1118/1.594240
[4]   Assessment of coronary artery disease by cardiac computed tomography - A scientific statement from the American Heart Association committee on cardiovascular imaging and intervention, council on cardiovascular radiology and intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology [J].
Budoff, Matthew J. ;
Achenbach, Stephan ;
Blumenthal, Roger S. ;
Carr, J. Jeffrey ;
Goldin, Jonathan G. ;
Greenland, Philip ;
Guerci, Alan D. ;
Lima, Joao A. C. ;
Rader, Daniel J. ;
Rubin, Geoffrey D. ;
Shaw, Leslee J. ;
Wiegers, Susan E. .
CIRCULATION, 2006, 114 (16) :1761-1791
[5]  
DALY RC, 1988, J THORAC CARDIOV SUR, V96, P19
[6]   Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenosis in an unselected consecutive patient population - Comparison with conventional invasive angiography [J].
Ehara, M ;
Surmely, JF ;
Kawai, M ;
Katoh, O ;
Matsubara, T ;
Terashima, M ;
Tsuchikane, E ;
Kinoshita, Y ;
Suzuki, T ;
Ito, T ;
Takeda, Y ;
Nasu, K ;
Tanaka, N ;
Murata, A ;
Suzuki, Y ;
Sato, K ;
Suzuki, T .
CIRCULATION JOURNAL, 2006, 70 (05) :564-571
[7]   Comparison of accuracy of 64-slice cardiovascular computed tomography with coronary angiography in patients with suspected coronary artery disease [J].
Fine, JJ ;
Hopkins, CB ;
Ruff, N ;
Newton, FC .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (02) :173-174
[8]   Multi-detector row CT systems and image-reconstruction techniques [J].
Flohr, TG ;
Schaller, S ;
Stierstorfer, K ;
Bruder, H ;
Ohnesorge, BM ;
Schoepf, UJ .
RADIOLOGY, 2005, 235 (03) :756-773
[9]   Experimental hypercholesterolemia differentially affects adventitial vasa vasorum and vessel structure of the left internal thoracic and coronary arteries [J].
Galili, O ;
Sattler, KJ ;
Herrmann, J ;
Woodrum, J ;
Olson, M ;
Lerman, LO ;
Lerman, A .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (04) :767-772
[10]   Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies [J].
Gies, M ;
Kalender, WA ;
Wolf, H ;
Suess, C ;
Madsen, MT .
MEDICAL PHYSICS, 1999, 26 (11) :2235-2247