Applications of ultrasound streaming and radiation force in biosensors

被引:88
作者
Kuznetsova, Larisa A. [1 ]
Coakley, W. Terence [1 ]
机构
[1] Cardiff Univ, Sch Biosci, Cardiff CF10 3TL, Wales
基金
英国生物技术与生命科学研究理事会;
关键词
acoustic radiation force; immumo-detection; antibody coated; flow-through biosensor; microfluidic; surface wave;
D O I
10.1016/j.bios.2006.08.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Direct radiation force (DRF) and acoustic streaming provide the main influences on the behaviour of particles in aqueous suspension in an ultrasound standing wave (USW). The direct radiation force, which drives suspended particles towards and concentrates them in acoustic pressure node planes, has been applied to rapidly transfer cells in small scale analytical separators. The DRF also significantly increased the sensitivity of latex agglutination test (LAT) by concentrating the particles of an analytical sample in the pressure node positions and hence greatly increasing the antibody-antigen encounter rate. Capture of biotinylated particles and spores on a coated acoustic reflector in a quarter wavelength USW resonator was DRF-enhanced by 70- and 100-fold, respectively compared to the situation in the absence of ultrasound. Acoustic streaming has been successfully employed for mixing small analytical samples. Cavitation micro-streaming substantially enhanced, through mixing, DNA hybridization and the capture efficiency of Escherichia coli K12 on the surface of immunomagnetic beads. Acoustic streaming induced in longitudinal standing wave and flexural plate wave immuno-sensors increased the detection of antigens by a factor of five and three times, respectively. Combined DRF and acoustic streaming effects enhanced the rate of the reaction between suspended mixture of cells and retroviruses. The examples of a biochip and an ultrasonic immuno-sensor implementing the DRF and acoustic streaming effects are also described in the review. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1567 / 1577
页数:11
相关论文
共 84 条
[1]   Highly sensitive flow-injection immunoassay system for rapid detection of bacteria [J].
Abdel-Hamid, I ;
Ivnitski, D ;
Atanasov, P ;
Wilkins, E .
ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) :99-108
[2]   SENSORS BASED ON PIEZOELECTRIC RESONATORS [J].
BENES, E ;
GROSCHL, M ;
BURGER, W ;
SCHMID, M .
SENSORS AND ACTUATORS A-PHYSICAL, 1995, 48 (01) :1-21
[3]   A novel ultrasound-enhanced latex agglutination test for the detection of antibodies against Mycobacterium tuberculosis in serum [J].
Bhaskar, S ;
Banavaliker, JN ;
Bhardwaj, K ;
Upadhyay, P .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 262 (1-2) :181-186
[4]   Piezoelectric quartz crystal biosensors [J].
Bunde, RL ;
Jarvi, EJ ;
Rosentreter, JJ .
TALANTA, 1998, 46 (06) :1223-1236
[5]   Microfluidic mixers: from microfabricated to self-assembling devices [J].
Campbell, CJ ;
Grzybowski, BA .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2004, 362 (1818) :1069-1086
[6]   Acoustic waves and the study of biochemical macromolecules and cells at the sensor-liquid interface [J].
Cavic, BA ;
Hayward, GL ;
Thompson, M .
ANALYST, 1999, 124 (10) :1405-1420
[7]   Ultrasonic treatment of liquid waste containing EDTA [J].
Chitra, S ;
Paramasivan, K ;
Sinha, PK ;
Lal, KB .
JOURNAL OF CLEANER PRODUCTION, 2004, 12 (04) :429-435
[8]  
Coakley WT, 1997, TRENDS BIOTECHNOL, V15, P506, DOI 10.1016/S0167-7799(97)01122-0
[9]  
Coakley WT, 2004, COLLOID SURFACE B, V34, P221, DOI 10.1016/j.colfsurb.2004.01.002
[10]   Emerging biomedical sensing technologies and their applications [J].
Coté, GL ;
Lec, RM ;
Pishko, MV .
IEEE SENSORS JOURNAL, 2003, 3 (03) :251-266