Semi-micro high-performance liquid chromatographic analysis of tiropramide in human plasma using column-switching

被引:7
作者
Baek, SK
Lee, SS
Park, EJ
Sohn, DH
Lee, HS [1 ]
机构
[1] Wonkwang Univ, Coll Pharm, Shinyongdong 570749, Iksan, South Korea
[2] Wonkwang Univ, Med Resources Res Ctr, Shinyongdong 570749, Iksan, South Korea
关键词
tiropramide; column-switching HPLC;
D O I
10.1016/S0731-7085(02)00570-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive column-switching semi-micro high-performance liquid chromatography method was developed for the direct analysis of tiropramide in human plasma. The plasma sample (100 mul) was directly injected onto Capcell Pak MF Ph-1 precolumn where deproteinization and analyte fractionation occurred. Tiropramide was then eluted into an enrichment column (Capcell Pak UG C-18) using acetonitrile-potassium phosphate (pH 7.0, 50 mM) (12:88, v/v) and was analyzed on a semi-micro C-18 analytical column using acetonitrile-potassium. phosphate (pH 7.0, 10 mM) (50:50, v/v). The method showed excellent sensitivity (limit of quantification 5 ng/ml), and good precision (C.V. less than or equal to 5.9%), and speed (total analysis time 20 min). The calibration curve was linear in the concentration range 5-200 ng/ml (coefficient of determination equal to 0.998). This method was successfully applied to the pharmacokinetic study of tiropramide in volunteers. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 9 条
[1]  
ARIGONI R, 1986, ARZNEIMITTEL-FORSCH, V36-1, P738
[2]   IDENTIFICATION OF METABOLITES OF TIROPRAMIDE IN HUMAN-URINE [J].
ARIGONI, R ;
CHISTE, R ;
MAKOVEC, F ;
SETNIKAR, I ;
BENFENATI, E ;
FANELLI, R .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (04) :205-209
[3]   Rapid microbore liquid chromatographic analysis of biphenyldimethyl dicarboxylate in human plasma with on-line column switching [J].
Jeong, CK ;
Kim, SB ;
Choi, SJ ;
Sohn, DH ;
Ko, GI ;
Lee, HS .
JOURNAL OF CHROMATOGRAPHY B, 2000, 738 (01) :175-179
[4]   Microbore high-performance liquid chromatographic determination of cisapride in rat serum samples using column switching [J].
Lee, HM ;
Choi, SJ ;
Jeong, CK ;
Kim, YS ;
Lee, KC ;
Lee, HS .
JOURNAL OF CHROMATOGRAPHY B, 1999, 727 (1-2) :213-217
[5]  
SETNIKAR I, 1988, ARZNEIMITTEL-FORSCH, V38-2, P1815
[6]   LOW CONCENTRATION DRUG ANALYSIS BY SEMI-MICROCOLUMN LIQUID-CHROMATOGRAPHY WITH A POLYMER-COATED MIXED-FUNCTION PRECOLUMN [J].
SHIROTA, O ;
SUZUKI, A ;
KANDA, T ;
OHTSU, Y ;
YAMAGUCHI, M .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (01) :29-35
[7]   Simultaneous determination of estriol and estriol 3-sulfate in serum by column-switching semi-micro high-performance liquid chromatography with ultraviolet and electrochemical detection [J].
Tagawa, N ;
Tsuruta, H ;
Fujinami, A ;
Kobayashi, Y .
JOURNAL OF CHROMATOGRAPHY B, 1999, 723 (1-2) :39-45
[8]  
Tinozzi S, 1984, Minerva Med, V75, P23
[9]  
TRABUCCHI E, 1986, PHARMATHERAPEUTICA, V4, P541