Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress comparison with 99mTc-Sestamibi SPECT imaging

被引:126
作者
Heinle, SK
Noblin, J
Goree-Best, P
Mello, A
Ravad, G
Mull, S
Mammen, P
Grayburn, PA
机构
[1] Vet Adm Med Ctr, Div Cardiol 111A, Dallas, TX 75216 USA
[2] Univ Texas, SW Med Ctr, Dept Internal Med, Div Cardiol, Dallas, TX USA
关键词
contrast media; echocardiography; perfusion; stress; tomography; adenosine;
D O I
10.1161/01.CIR.102.1.55
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Harmonic power Doppler imaging (HPDI) is a novel technique for assessing myocardial perfusion by contrast echocardiography in humans. The purpose of this study was to compare myocardial perfusion by HPDI with that obtained by Tc-99m-sestamibi single photon emission computed tomography (SPECT) during rest and pharmacological stress, Methods and Results-HPDI was performed on 123 patients who were referred for SPECT imaging for known or suspected coronary artery disease. Images were obtained at baseline and during adenosine infusion (0.14 mg.kg(-1)min(-1)x6 minutes) in 3 apical views. Myocardial perfusion by HPDI was graded for each coronary territory as absent, patchy, or full. The persistence of absent or patchy myocardial perfusion by HPDI between rest and adenosine was interpreted as a fixed defect, whereas any decrease in perfusion grade was interpreted as a reversible defect. Overall concordance between HPDI and SPECT was 83 (81%) of 103 for normal versus abnormal perfusion. Agreement between the 3 methods for each of the 3 coronary territories was 81% (kappa=0.57) for the left anterior descending artery, 76% (kappa=0.52) for the right coronary artery, and 72% (kappa=0.40) for the left circumflex artery. Discrepancies between the 2 techniques were most notable in the circumflex territory, where fixed defects were observed in 33% by HPDI but in only 14% by SPECT (chi(2)=15.8, P=0.0001). Conclusions-This study demonstrates that HPDI can reliably detect myocardial perfusion during pharmacological stress, although there was a significantly higher number of falsely abnormal results in the circumflex territory.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 25 条
[11]  
MILLER JJ, IN PRESS J AM SOC EC
[12]   Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography [J].
Pelberg, RA ;
Wei, K ;
Kamiyama, N ;
Sklenar, J ;
Bin, JP ;
Kaul, S .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (02) :85-93
[13]   Measurement of fractional flow reserve to assess the functional severity of coronary-artery stenoses [J].
Pijls, NHJ ;
DeBruyne, B ;
Peels, K ;
VanderVoort, PH ;
Bonnier, HJRM ;
Bartunek, J ;
Koolen, JJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (26) :1703-1708
[14]   Detection of regional perfusion abnormalities during adenosine stress echocardiography with intravenous perfluorocarbon-exposed sonicated dextrose albumin [J].
Porter, TR ;
Kricsfeld, A ;
Deligonul, U ;
Xie, F .
AMERICAN HEART JOURNAL, 1996, 132 (01) :41-47
[15]  
Rocchi Guido, 1999, Journal of the American College of Cardiology, V33, p480A
[16]   AN ASSOCIATION BETWEEN COLLATERAL BLOOD-FLOW AND MYOCARDIAL VIABILITY IN PATIENTS WITH RECENT MYOCARDIAL-INFARCTION [J].
SABIA, PJ ;
POWERS, ER ;
RAGOSTA, M ;
SAREMBOCK, IJ ;
BURWELL, LR ;
KAUL, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 327 (26) :1825-1831
[17]   Power Doppler harmonic imaging: A feasibility study of a new technique for the assessment of myocardial perfusion [J].
Senior, R ;
Kaul, S ;
Soman, P ;
Lahiri, A .
AMERICAN HEART JOURNAL, 2000, 139 (02) :245-251
[18]   Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second-generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection [J].
Skyba, DM ;
Camarano, G ;
Goodman, NC ;
Price, RJ ;
Skalak, TC ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1292-1300
[19]   Stimulated acoustic emission - Nonbackscatter contrast effect of microbubbles seen with harmonic power Doppler imaging [J].
Tiemann, K ;
Becher, H ;
Bimmel, D ;
Schlief, R ;
Nanda, NC .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1997, 14 (01) :65-69
[20]   RELATION BETWEEN MYOCARDIAL BLOOD-FLOW AND THE SEVERITY OF CORONARY-ARTERY STENOSIS [J].
UREN, NG ;
MELIN, JA ;
DEBRUYNE, B ;
WIJNS, W ;
BAUDHUIN, T ;
CAMICI, PG .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 330 (25) :1782-1788