Micro flow cytometer chip integrated with micro-pumps/micro-valves for multi-wavelength cell counting and sorting

被引:21
作者
Chang, Chen-Min [1 ]
Hsiung, Suz-Kai [1 ]
Lee, Gwo-Bin [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS | 2007年 / 46卷 / 5A期
关键词
flow cytometer; microfluidics; MEMS; micropumps;
D O I
10.1143/JJAP.46.3126
中图分类号
O59 [应用物理学];
学科分类号
摘要
Flow cytometry is a popular technique for counting and sorting of individual cells. This study presents a new chip-based flow cytometer capable of cell injection, counting and switching in an automatic format. The new microfluidic system is also capable of multi-wavelength detection of fluorescence-labeled cells by integrating multiple buried optical fibers within the chip. Instead of using large-scale syringe pumps, this study integrates micro-pumps and micro-valves to automate the entire cell injection and sorting process. By using pneumatic serpentine-shape (S-shape) micro-pumps to drive sample and sheath flows, the developed chip can generate hydrodynamic focusing to allow cells to pass detection regions in sequence. Two pairs of optical fibers are buried and aligned with the microchannels, which can transmit laser light sources with different wavelengths and can collect induced fluorescence signals. The cells labeled with different fluorescent dyes can be excited by the corresponding light source at different wavelengths. The fluorescence signals are then collected by avalanche photodiode (APD) sensors. Finally, a flow switching device composed of three pneumatic micro-valves is used for cell sorting function. Experimental data show that the developed flow cytometer can distinguish specific cells with different dye-labeling from mixed cell samples in one single process. The target cell samples can be also switched into appropriate outlet channels utilizing the proposed microvalve device. The developed microfluidic system is promising for miniature cell-based biomedical applications.
引用
收藏
页码:3126 / 3134
页数:9
相关论文
共 38 条
[21]   Micromachined pre-focused M x N flow switches for continuous multi-sample injection [J].
Lee, GB ;
Hwei, BH ;
Huang, GR .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2001, 11 (06) :654-661
[22]   The hydrodynamic focusing effect inside rectangular microchannels [J].
Lee, Gwo-Bin ;
Chang, Chih-Chang ;
Huang, Sung-Bin ;
Yang, Ruey-Jen .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2006, 16 (05) :1024-1032
[23]   Micromachined flow cytometers with embedded etched optic fibers for optical detection [J].
Lin, CH ;
Lee, GB .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (03) :447-453
[24]   A new fabrication process for ultra-thick microfluidic microstructures utilizing SU-8 photoresist [J].
Lin, CH ;
Lee, GB ;
Chang, BW ;
Chang, GL .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (05) :590-597
[25]   Go with the flow - use of flow cytometry in environmental microbiology [J].
Porter, J ;
Deere, D ;
Hardman, M ;
Edwards, C ;
Pickup, R .
FEMS MICROBIOLOGY ECOLOGY, 1997, 24 (02) :93-101
[26]  
Raiteri R., 2002, Materials Today, V5, P22, DOI DOI 10.1016/S1369-7021(02)05139-8
[27]   Flow cytometry in biotechnology [J].
Rieseberg, M ;
Kasper, C ;
Reardon, KF ;
Scheper, T .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2001, 56 (3-4) :350-360
[28]   Fabrication of glassy carbon microstructures by soft lithography [J].
Schueller, OJA ;
Brittain, ST ;
Whitesides, GM .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 72 (02) :125-139
[29]  
SILVA CWD, 1999, VIBRATION FUNDAMENTA, P334
[30]   Microchannel-assisted thermal-lens spectrometry for microchip analysis [J].
Tamaki, E ;
Hibara, A ;
Tokeshi, M ;
Kitamori, T .
JOURNAL OF CHROMATOGRAPHY A, 2003, 987 (1-2) :197-204