CEC separation of heterocyclic amines using methacrylate monolithic columns

被引:14
作者
Barcelo-Barrachina, Elena [1 ]
Moyano, Encarnacion [1 ]
Puignou, Lluis [1 ]
Galceran, Maria Teresa [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
CEC; CEC-MS; heterocyclic amines; methacrylate; monolithic;
D O I
10.1002/elps.200600356
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
Two methacrylate-based monolithic columns, one with a negatively charged group (sulfonic group) and another with a new monomer N,N-dimethylamino ethyl acrylate (DMAEA), were prepared and tested for the separation of basic compounds by CEC. This new monolithic stationary phase was prepared by the in situ polymerization of DMAEA with butyl methacrylate and ethylene dimethacrylate, using a ternary porogenic solvent consisting of water, 1-propanol and 1,4-butanediol. The performance of this column was evaluated by means ofthe analysis of a family of heterocyclic amines. Separation conditions such as pH, amount of organic modifier, ionic strength and elution mode (normal or counterdirectional flow) were studied. At the optimal running electrolyte composition, and using the counterdirectional mode, symmetrical electrochromatographic peaks were obtained, with the number of theoretical plates up to 30 000 and a good resolution between closely related peaks. The 2-acrylamido-2-methyl-1-propane-sulfonic acid column was used for CEC-MS, taking advantage of the compatibility of its elution mode (normal flow) with the MS coupling.
引用
收藏
页码:1704 / 1713
页数:10
相关论文
共 47 条
[1]
State-of-the-art of the hyphenation of capillary electrochromatography with mass spectrometry [J].
Barceló-Barrachina, E ;
Moyano, E ;
Galceran, MT .
ELECTROPHORESIS, 2004, 25 (13) :1927-1948
[2]
Recent advances in polymeric monolithic stationary phases for electrochromatography in capillaries and chips [J].
Bedair, M ;
El Rassi, Z .
ELECTROPHORESIS, 2004, 25 (23-24) :4110-4119
[3]
Analysis of heterocyclic amines in chicken by liquid chromatography with electrochemical detection [J].
Bermudo, E ;
Ruiz-Calero, V ;
Puignou, L ;
Galceran, MT .
ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) :83-90
[4]
Control of dispersion in capillary electrochromatography coupled to UV and mass spectrometric detection [J].
Boughtflower, RJ ;
Paterson, CJ ;
Knox, JH .
JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) :409-420
[5]
Occurrence of heterocyclic amines in several home-cooked meat dishes of the Spanish diet [J].
Busquets, R ;
Bordas, M ;
Toribio, F ;
Puignou, L ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (01) :79-86
[6]
Practical aspects of using methacrylate-ester-based monolithic columns in capillary electrochromatography [J].
Eeltink, S ;
Rozing, GP ;
Schoenmakers, PJ ;
Kok, WT .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (01) :74-79
[7]
Enlund AM, 2001, ELECTROPHORESIS, V22, P511, DOI 10.1002/1522-2683(200102)22:3<511::AID-ELPS511>3.0.CO
[8]
2-W
[9]
Reversed-phase electrochromatography of proteins on modified continuous beds using normal-flow and counterflow gradients.: Theoretical and practical considerations [J].
Ericson, C ;
Hjertén, S .
ANALYTICAL CHEMISTRY, 1999, 71 (08) :1621-1627
[10]
Monolithic columns with mixed modes of reversed-phase and anion-exchange stationary phase for capillary electrochromatography [J].
Fu, HJ ;
Xie, CH ;
Xiao, H ;
Dong, J ;
Hu, JW ;
Zou, HF .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :237-244