A transparent flow gating interface for the coupling of microcolumn LC with CZE in a comprehensive two-dimensional system

被引:160
作者
Hooker, TF [1 ]
Jorgenson, JW [1 ]
机构
[1] UNIV N CAROLINA, DEPT CHEM, CHAPEL HILL, NC 27599 USA
关键词
D O I
10.1021/ac970342w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new interface for the coupling of microcolumn highperformance liquid chromatography (micro-HPLC) with capillary zone electrophoresis (GZE) is presented. The new interface is based on the original now gated design developed in this laboratory but is now made from a clear plastic which allows for the direct observation and routine manipulation of the micro-HPLC and CZE capillaries, Ar, with the original design, a transverse flow of CZE buffer controls analyte injection onto the CZE capillary. To evaluate the reproducibility of the interface, 400 consecutive CZE separations of a mixture of fluorescein 5-isothiocyanate (FITC)-labeled phenylalanine and glutamic acid are performed over a 2 h period. The percent relative standard deviations (% RSD) of the peak height, peak area, and migration times of 400 nuns of FITC-phenylalanine are 2.5, 3, and 0.07%, respectively, and of FITC-glutamic acid are 2.5, 3.5, and 0.07%, respectively. The % RSDs of the peak height, peak area, and migration time were reduced to 0.7, 0.6, and 0.02%, respectively, by normalizing the results of glutamic acid to that of phenylalanine. This interface also introduces little extra-column band broadening into the system as evidenced by plate counts of 480 000 for FITC-phenylalanine and FITC-glutamic acid achieved ip less than 35 s, The clarity of the interface allows the flow gating and injection processes to be directly observed using a colored dye solution. Real-time images of an injection sequence using the interface have been acquired with the aid of video instrumentation and are presented to illustrate the injection process.
引用
收藏
页码:4134 / 4142
页数:9
相关论文
共 39 条
[21]   ONLINE INTERFACE BETWEEN MICRODIALYSIS AND CAPILLARY ZONE ELECTROPHORESIS [J].
LADA, MW ;
SCHALLER, G ;
CARRIGER, MH ;
VICKROY, TW ;
KENNEDY, RT .
ANALYTICA CHIMICA ACTA, 1995, 307 (2-3) :217-225
[22]   Quantitative in vivo monitoring of primary amines in rat caudate nucleus using microdialysis coupled by a flow-gated interface to capillary electrophoresis with laser-induced fluorescence detection [J].
Lada, MW ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 1996, 68 (17) :2790-2797
[23]   Quantitative in vivo measurements using microdialysis on-line with capillary zone electrophoresis [J].
Lada, MW ;
Kennedy, RT .
JOURNAL OF NEUROSCIENCE METHODS, 1995, 63 (1-2) :147-152
[24]   2-DIMENSIONAL SEPARATIONS OF PEPTIDES AND PROTEINS BY COMPREHENSIVE LIQUID-CHROMATOGRAPHY CAPILLARY-ELECTROPHORESIS [J].
LARMANN, JP ;
LEMMO, AV ;
MOORE, AW ;
JORGENSON, JW .
ELECTROPHORESIS, 1993, 14 (5-6) :439-447
[25]  
LARMANN JP, 1993, THESIS U N CAROLINA
[26]   2-DIMENSIONAL PROTEIN SEPARATION BY MICROCOLUMN SIZE-EXCLUSION CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS [J].
LEMMO, AV ;
JORGENSON, JW .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :213-220
[27]   TRANSVERSE FLOW GATING INTERFACE FOR THE COUPLING OF MICROCOLUMN-LC WITH CZE IN A COMPREHENSIVE 2-DIMENSIONAL SYSTEM [J].
LEMMO, AV ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1576-1581
[28]  
LEMMO AV, UNPUB J MICROCOL SEP
[29]  
LEMMO AV, 1994, THESIS U N CAROLINA
[30]   Comprehensive on-line RPLC-CZE-MS of peptides [J].
Lewis, KC ;
Opiteck, GJ ;
Jorgenson, JW ;
Sheeley, DM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (05) :495-500