A disposable amperometric enzyme immunosensor for rapid detection of Vibrio parahaemolyticus in food based on agarose/Nano-Au membrane and screen-printed electrode

被引:78
作者
Zhao, Guangying [1 ]
Xing, Fengfeng [1 ]
Deng, Shaoping [1 ]
机构
[1] Zhejiang Univ, Dept Food Qual & Safety, Food Safety Key Lab Zhejiang Province, Hangzhou 310035, Peoples R China
基金
中国国家自然科学基金;
关键词
rapid detection of food pathogen; electrochemical immunosensor; vibrio parahaemolyticus; agarose; screen-printed electrode; Nano-Au;
D O I
10.1016/j.elecom.2007.01.036
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Recent outbreaks of foodborne illnesses continue to support the need for rapid and sensitive methods for detection of foodborne pathogens. A disposable electrochemical immunosensor for detection of Vibrio parahaemolyticus (VP) based on the screen-printed electrode (SPE) coated with agarose/Nano-Au membrane and horseradish peroxidase (HRP) labeled VP antibody (HRP-anti-VP) has been developed in this paper. Then, the immunosensor was characterized by cyclic voltammetry (CV) and laser scanning confocal microscope (LSCM). The immunosensor was incubated with the one-step immunoassay format involving VP for 30 min at room temperature (25 0.5 degrees C). The access of the active center of HRP catalyzing the oxidation reaction of thionine by H2O2 was partly inhibited by VP, which connected on the surface of the immunosensor by immunoreaction. VP could be quantificationally detected according to the shift of reduction current while CV was used as electrochemical means to detect the products of the enzymatic reaction. Under the optimum conditions of immunoreaction and electrochemical detection, VP was rapidly detectable by sigmoidal curve method and form a linear calibration between 10(5) and 10(9) cfu/ml with an associated detection limit of 7.374 x 10(4) cfu/ml (S/N = 3). The immunosensor had acceptable specificity, reproducibility, stability and accuracy, indicating that the immunosensor could satisfy the need of practical sample detection. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1263 / 1268
页数:6
相关论文
共 23 条
[1]   Highly sensitive flow-injection immunoassay system for rapid detection of bacteria [J].
Abdel-Hamid, I ;
Ivnitski, D ;
Atanasov, P ;
Wilkins, E .
ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) :99-108
[2]   Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents [J].
Andreescu, S ;
Noguer, T ;
Magearu, V ;
Marty, JL .
TALANTA, 2002, 57 (01) :169-176
[3]   Reagentless and regenerable immunosensor for monitoring of immunoglobulin G based on non-separation immunoassay [J].
Aoyagi, S ;
Imai, R ;
Sakai, K ;
Kudo, M .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :791-795
[4]   Detection of Vibrio parahaemolyticus in cockle (Anadara granosa) by PCR [J].
Bilung, LM ;
Radu, S ;
Bahaman, AR ;
Rahim, RA ;
Napis, S ;
Ling, MWCV ;
Tanil, GB ;
Nishibuchi, M .
FEMS MICROBIOLOGY LETTERS, 2005, 252 (01) :85-88
[5]   Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode [J].
Darain, F ;
Park, SU ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :773-780
[6]   Immunosensors [J].
Gizeli, E ;
Lowe, CR .
CURRENT OPINION IN BIOTECHNOLOGY, 1996, 7 (01) :66-71
[7]   NOVEL METHOD TO CHEMICALLY IMMOBILIZE ANTIBODY ON NYLON AND ITS APPLICATION TO THE RAPID AND DIFFERENTIAL DETECTION OF 2 VIBRIO-PARAHAEMOLYTICUS TOXINS IN A MODIFIED ENZYME-LINKED-IMMUNOSORBENT-ASSAY [J].
HONDA, T ;
MIWATANI, T ;
YABUSHITA, Y ;
KOIKE, N ;
OKADA, K .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1995, 2 (02) :177-181
[8]  
KAFERSTEIN F, 2004, B WORLD HEALTH ORGAN, V33, P725
[9]  
Khan AA, 2002, FEMS MICROBIOL LETT, V206, P209, DOI 10.1111/j.1574-6968.2002.tb11011.x
[10]   Development of an amperometric biosensor based on acetylcholine esterase covalently bound to a new support material [J].
Khayyami, M ;
Pita, MTP ;
Garcia, NP ;
Johansson, G ;
Danielsson, B ;
Larsson, PO .
TALANTA, 1998, 45 (03) :557-563