Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol

被引:95
作者
Arya, Sunil K. [1 ]
Chornokur, Ganna [1 ]
Venugopal, Manju [2 ]
Bhansali, Shekhar [1 ]
机构
[1] Univ S Florida, Dept Elect Engn, Bio MEMS & Microsyst Lab, Tampa, FL 33620 USA
[2] Guided Therapeut Inc, Norcross, GA 30092 USA
关键词
Cortisol; Self-assembled monolayer; Electrochemical impedance; Immunosensor; Dithiobis(succinimidyl propionate); Disposable biosensor; LABEL-FREE DETECTION; IMPEDANCE SPECTROSCOPY; IMPEDIMETRIC IMMUNOSENSOR; ENZYME-IMMUNOASSAY; SERUM; BIOSENSOR; SALIVA; PLASMA; RADIOIMMUNOASSAY; FLUID;
D O I
10.1016/j.bios.2010.03.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Gold microelectrode arrays functionalized with dithiobis(succinimidyl propionate) self-assembled monolayer (SAM) have been used to fabricate an ultrasensitive, disposable, electrochemical cortisol immunosensor. Cortisol specific monoclonal antibody (C-Mab) was covalently immobilized on the surface of gold microelectrode array and the sensors were exposed to solutions with different cortisol concentration. After C-Mab binding, unreacted active groups of DTSP were blocked using ethanol amine (EA) and label-free electrochemical impedance (EIS) technique was used to determine cortisol concentration. EIS results confirmed that EA/C-Mab/DTSP/Au based biosensor can accurately detect cortisol in the range of 1 pM-100 nM. The biosensor was successfully used for the measurement of cortisol in interstitial fluid in vitro. This research establishes the feasibility of using impedance based biosensor architecture for disposable, wearable cortisol detector. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2296 / 2301
页数:6
相关论文
共 54 条
[1]   A fluorimetric assay for cortisol [J].
Appel, D ;
Schmid, RD ;
Dragan, CA ;
Bureik, M ;
Urlacher, VB .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) :182-186
[2]   Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor [J].
Arya, Sunil K. ;
Pandey, Pratibha ;
Singh, Surinder P. ;
Datta, Monika ;
Malhotra, Bansi D. .
ANALYST, 2007, 132 (10) :1005-1009
[3]   Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique [J].
Arya, Sunil K. ;
Solanki, Pratima R. ;
Singh, S. P. ;
Kaneto, K. ;
Pandey, Manoj K. ;
Datta, Monika ;
Malhotra, Bansi D. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2516-2524
[4]  
Atkins P.W., 2001, PHYS CHEM, P827
[5]  
Azcon J.R., 2008, BIOSENS BIOELECTRON, V23, P1367
[6]   Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid [J].
Bantle, JP ;
Thomas, W .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1997, 130 (04) :436-441
[7]   An electrochemical impedance immunosensor with signal amplification based on Au-colloid labeled antibody complex [J].
Chen, Huan ;
Jiang, Jian-Hui ;
Huang, Yong ;
Deng, Ting ;
Li, Ji-Shan ;
Shen, Guo-Li ;
Yu, Ru-Qin .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 117 (01) :211-218
[8]   Radioimmunoassay for cortisol in pig saliva and serum [J].
Cook, NJ ;
Schaefer, AL ;
Lepage, P ;
Jones, SDM .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (02) :395-399
[9]   Validation of a simple method of estimating plasma free cortisol: Role of cortisol binding to albumin [J].
Dorin, Richard I. ;
Pai, Hemanth K. ;
Ho, Jui T. ;
Lewis, John G. ;
Torpy, David J. ;
Urban, Frank K., III ;
Qualls, Clifford R. .
CLINICAL BIOCHEMISTRY, 2009, 42 (1-2) :64-71
[10]   Urinary high performance reverse phase chromatography cortisol and cortisone analyses before and at the end of a race in elite cyclists [J].
Gatti, R ;
Cappellin, E ;
Zecchin, B ;
Antonelli, G ;
Spinella, P ;
Mantero, F ;
De Palo, EF .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2) :51-56