In-situ near-infrared spectroscopy monitoring of the lyophilization process

被引:48
作者
Brülls, M [1 ]
Folestad, S
Sparén, A
Rasmuson, A
机构
[1] AstraZeneca R&D Molndal, SE-43183 Molndal, Sweden
[2] AstraZeneca Tablet Prod Sweden, SE-15185 Sodertalje, Sweden
[3] Chalmers Univ Technol, Dept Chem Engn Design, SE-41296 Gothenburg, Sweden
关键词
lyophilization; freeze-drying; process; NIR; monitoring; in-situ;
D O I
10.1023/A:1022680810474
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Purpose. The purpose of this work was to demonstrate the feasibility of using near-infrared spectroscopy (NIRS) to monitor the freeze-drying process in-situ. Methods. The experiment was performed in a pilot-scale freeze-dryer, in which the NIRS probe was interfaced using a lead-through to the lyophilizer. Special equipment for the sample presentation was developed. NIRS measurements were made using a FT (Fourier transform)- NIR spectrometer fitted with a single fiber reflectance probe. Results. The physical changes, that is, freezing, sublimation, and desorption, generated significant spectral changes. There was good agreement between NIRS monitoring and product temperature monitoring about the freezing process and the transition from frozen solution to ice-free material. The NIRS monitoring also provided new information about the process that was not possible to detect with product temperature monitoring, such as the rate of the desorption process and the steady-state where the drying was complete. The NIRS monitoring yields significantly more information about the actual process and essentially explains the observed changes of the product temperature during the lyophilization process. Conclusions. NIRS monitoring is a viable tool for in-situ monitoring, both qualitatively and quantitatively. It can facilitate investigations of the drying process within a sample. The small volume monitored makes sample presentation very important.
引用
收藏
页码:494 / 499
页数:6
相关论文
共 30 条
[1]   Quantitative analysis of film coating in a fluidized bed process by in line NIR spectrometry and multivariate batch calibration [J].
Andersson, M ;
Folestad, S ;
Gottfries, J ;
Johansson, MO ;
Josefson, M ;
Wahlund, KG .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2099-2108
[2]   Monitoring of a film coating process for tablets using near infrared reflectance spectrometry [J].
Andersson, M ;
Josefson, M ;
Langkilde, FW ;
Wahlund, KG .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) :27-37
[3]  
[Anonymous], 1990, FREEZE DRYING FOOD I
[4]  
BARDAT A, 1993, J PARENT SCI TECHN, V47, P293
[5]   Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy [J].
Berntsson, O ;
Danielsson, LG ;
Lagerholm, B ;
Folestad, S .
POWDER TECHNOLOGY, 2002, 123 (2-3) :185-193
[6]  
CAMERON P, 1997, GOOD PHARM FREEZE DR
[7]  
Cavatur R K, 1998, Pharm Dev Technol, V3, P579, DOI 10.3109/10837459809028642
[8]  
CONNELLY JP, 1993, J PARENT SCI TECHN, V47, P70
[9]   On-line monitoring of powder blending with near-infrared spectroscopy [J].
De Maesschalck, R ;
Sanchez, FC ;
Massart, DL ;
Doherty, P ;
Hailey, P .
APPLIED SPECTROSCOPY, 1998, 52 (05) :725-731
[10]   Dry Drops:: a new preservative-free drug delivery system [J].
Diestelhorst, M ;
Grunthal, S ;
Süverkrüp, R .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1999, 237 (05) :394-398