Determination of drugs of abuse in water by solid-phase extraction, derivatisation and gas chromatography-ion trap-tandem mass spectrometry

被引:123
作者
Gonzalez-Marino, Iria [1 ]
Benito Quintana, Jose [1 ]
Rodriguez, Isaac [1 ]
Cela, Rafael [1 ]
机构
[1] Univ Santiago de Compostela, Dept Analyt Chem Nutr & Food Sci, IIAA Inst Food Anal & Res, Santiago De Compostela 15782, Spain
关键词
Illicit drugs; Water samples; Gas chromatography; Ion trap-mass spectrometry; Solid-phase extraction; Derivatisation; URBAN WASTE-WATER; SURFACE-WATER; ILLICIT DRUGS; STIMULATORY DRUGS; SEWAGE WATER; METABOLITES; COCAINE; PHARMACEUTICALS; IDENTIFICATION; CANNABINOIDS;
D O I
10.1016/j.chroma.2010.01.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An alternative method for the sensitive determination of several drugs Of abuse and some of their metabolites in surface and sewage water samples is proposed Analytes are concentrated using a solid-phase extraction (SPE) sorbent, converted into the corresponding trimethylsilyl derivatives and selectively determined by gas chromatography (GC) with tandem mass spectrometry (MS/MS) detection Parameters affecting the performance of extraction, derivatisation and determination steps are systematically investigated Moreover, the stability of target analytes in sewage water samples is discussed Under final working conditions, water samples were adjusted at pH 8 5 and concentrated using a 200 mg OASIS HLB SPE cartridge Analytes were sequentially eluted with ethyl acetate followed by acetone and silylated using N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) The reaction was completed in 60 min at 80 degrees C and the mixture injected directly in the GC-MS/MS system without further purification in most cases, analytes presented a poor stability in sewage water samples, however. once they are submitted to the SPE process, cartridges can be stored at -20 degrees C for at least 3 Months Without significant degradation and/or inter-conversion reactions of illicit drugs The proposed method provided recoveries over 74% and LODs between 0 8 and 15 ng/L for rivet and treated wastewater samples In the case of raw wastewater slightly worse recoveries, between 63 and 137%. and similar LODs were attained Analysis of a limited number of waste and Surface water samples confirmed the presence of several illicit drugs ill the aquatic environment. with the highest levels and frequency corresponding to benzoylecgonine, the main metabolite of cocaine (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:1748 / 1760
页数:13
相关论文
共 29 条
[1]   Simultaneous ultra-high-pressure liquid chromatography-tandem mass spectrometry determination of amphetamine and amphetamine-like stimulants, cocaine and its metabolites, and a cannabis metabolite in surface water and urban wastewater [J].
Bijlsma, Lubertus ;
Sancho, Juan V. ;
Pitarch, Elena ;
Ibanez, Maria ;
Hernandez, Felix .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) :3078-3089
[2]   Trace determination of cannabinoids and opiates in wastewater and surface waters by ultra-performance liquid chromatography-tandem mass spectrometry [J].
Boleda, M. Rosa ;
Galceran, M. Teresa ;
Ventura, Francesc .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1175 (01) :38-48
[3]   Using environmental analytical data to estimate levels of community consumption of illicit drugs and abused pharmaceuticals [J].
Bones, Jonathan ;
Thomas, Kevin V. ;
Paull, Brett .
JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (07) :701-707
[4]   Mass spectrometric analysis of illicit drugs in wastewater and surface water [J].
Castiglioni, Sara ;
Zuccato, Ettore ;
Chiabrando, Chiara ;
Fanelli, Roberto ;
Bagnati, Renzo .
MASS SPECTROMETRY REVIEWS, 2008, 27 (04) :378-394
[5]   Identification and measurement of illicit drugs and their metabolites in urban wastewater by liquid chromatography-tandem mass spectrometry [J].
Castiglioni, Sara ;
Zuccato, Ettore ;
Crisci, Elisabetta ;
Chiabrando, Chiara ;
Fanelli, Roberto ;
Bagnati, Renzo .
ANALYTICAL CHEMISTRY, 2006, 78 (24) :8421-8429
[6]   Transplantation of fetal kidney cells: Neuroprotection and neuroregeneration [J].
Chiang, Yung-Hsiao ;
Borlongan, Cesario V. ;
Zhou, Feng C. ;
Hoffer, Barry J. ;
Wang, Yun .
CELL TRANSPLANTATION, 2005, 14 (01) :1-9
[7]  
Daughton C.G., 2001, ACS S SER, V791, P348, DOI DOI 10.1021/BK-2001-0791
[8]  
*EMCDDA, 2006, ANN REP 2006
[9]   Box-Behnken design: An alternative for the optimization of analytical methods [J].
Ferreira, S. L. C. ;
Bruns, R. E. ;
Ferreira, H. S. ;
Matos, G. D. ;
David, J. M. ;
Brandao, G. C. ;
da Silva, E. G. P. ;
Portugal, L. A. ;
dos Reis, P. S. ;
Souza, A. S. ;
dos Santos, W. N. L. .
ANALYTICA CHIMICA ACTA, 2007, 597 (02) :179-186
[10]   Analysis of cocaine and its principal metabolites in waste and surface water using solid-phase extraction and liquid chromatography-ion trap tandem mass spectrometry [J].
Gheorghe, Adriana ;
van Nuijs, Alexander ;
Pecceu, Bert ;
Bervoets, Lieven ;
Jorens, Philippe G. ;
Blust, Ronny ;
Neels, Hugo ;
Covaci, Adrian .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (04) :1309-1319