Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or:: When does ESI turn into nano-ESI?

被引:433
作者
Schmidt, A
Karas, M
Dülcks, T
机构
[1] Univ Frankfurt, Inst Pharmaceut Chem, D-60590 Frankfurt, Germany
[2] Univ Bremen, Dept Biol & Chem, Bremen, Germany
关键词
D O I
10.1016/S1044-0305(03)00128-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In nano-ESI MS, the qualitative and quantitative characteristics of mass spectra vary considerably upon the use of different spraying conditions, i.e., aperture of the spraying needle and the voltage applied. The major parameters affected by the aperture size is the liquid flow rate which determines the initial droplet size and the current emitted upon the spray process, as described by different models of the ESI process. In the present study, the effect of flow rate on ion signals was studied systematically using mixtures of compounds with different physicochemical properties (i.e., detergent/oligosaccharide and oligosaccharide/peptide). For these model systems, the functional dependence of certain analyte-ion ratios upon the flow rate can be correlated to changes in analyte partition during droplet fission prior to ion release. Analyte suppression is practically absent at minimal flow rates below 20 nL/min. (C) 2003 American Society for Mass Spectrometry.
引用
收藏
页码:492 / 500
页数:9
相关论文
共 36 条
[21]   PARAMETRIC STUDIES OF ELECTROHYDRODYNAMIC SPRAYING [J].
PFEIFER, RJ ;
HENDRICK.CD .
AIAA JOURNAL, 1968, 6 (03) :496-+
[22]   FACTORS AFFECTING THE IONIZATION EFFICIENCY OF QUATERNARY AMMONIUM-COMPOUNDS IN ELECTROSPRAY IONSPRAY MASS-SPECTROMETRY [J].
RAFFAELLI, A ;
BRUINS, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (06) :269-275
[23]   Influence of pressure in the first pumping stage on analyte desolvation and fragmentation in nano-ESI MS [J].
Schmidt, A ;
Bahr, U ;
Karas, M .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :6040-6046
[24]   Physical/chemical separations in the break-up of highly charged droplets from electrosprays [J].
Tang, KQ ;
Smith, RD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (03) :343-347
[25]   DEPENDENCE OF ION INTENSITY IN ELECTROSPRAY MASS-SPECTROMETRY ON THE CONCENTRATION OF THE ANALYTES IN THE ELECTROSPRAYED SOLUTION [J].
TANG, L ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3654-3668
[26]  
Van Berkel G. J., 1997, ELECTROSPRAY IONIZAT, P65
[27]  
Van Berkel GJ, 2000, J AM SOC MASS SPECTR, V11, P951
[28]  
Van Berkel GJ, 2000, J MASS SPECTROM, V35, P773, DOI 10.1002/1096-9888(200007)35:7<773::AID-JMS4>3.0.CO
[29]  
2-6
[30]   Effects of solvent and counterion on ion pairing and observed charge states of diquaternary ammonium salts in electrospray ionization mass spectrometry [J].
Wang, GD ;
Cole, RB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (10) :1050-1058