Fundamentals and applications of electrospray ionization mass spectrometry for petroleum characterization

被引:57
作者
Qian, K [1 ]
Edwards, KE [1 ]
Diehl, JH [1 ]
Green, LA [1 ]
机构
[1] ExxonMobil Res & Engn Co, Annandale, NJ 08801 USA
关键词
D O I
10.1021/ef049883w
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
We are reporting a study of the fundamental and application aspects of positive-ion electrospray ionization (ESI+) for petroleum characterization. In the positive-ion mode, basic nitrogen molecules (typically pyridinic molecules) form predominantly protonated molecule ions. Most other molecular types, such as paraffins, naphthenes, aromatics, and thiophenoaromatics, are largely not ionized by ESI. Metalloporphyrins and neutral nitrogens show little response. The effects of acid and analyte concentrations, and instrumental conditions, were evaluated. Increasing the acid concentration promotes the ionization of the low-molecular-weight bases but has minimal impact on high-molecular-weight species. Analyses of low- and high-molecular-weight petroleum fractions and their mixtures showed minimal mass discrimination. Cone and extraction voltages have a significant impact on ESI responses, particularly on aliphatic amines. Linear dynamic range exists at lower analyte concentrations (< 10(-5) M).
引用
收藏
页码:1784 / 1791
页数:8
相关论文
共 37 条
[31]   PRINCIPLES AND PRACTICE OF ELECTROSPRAY IONIZATION - MASS-SPECTROMETRY FOR LARGE POLYPEPTIDES AND PROTEINS [J].
SMITH, RD ;
LOO, JA ;
LOO, RRO ;
BUSMAN, M ;
UDSETH, HR .
MASS SPECTROMETRY REVIEWS, 1991, 10 (05) :359-451
[32]   Determination of polycyclic aromatic hydrocarbons by liquid chromatography-electrospray ionization mass spectrometry using silver nitrate as a post-column reagent [J].
Takino, M ;
Daishima, S ;
Yamaguchi, K ;
Nakahara, T .
JOURNAL OF CHROMATOGRAPHY A, 2001, 928 (01) :53-61
[33]   DEPENDENCE OF ION INTENSITY IN ELECTROSPRAY MASS-SPECTROMETRY ON THE CONCENTRATION OF THE ANALYTES IN THE ELECTROSPRAYED SOLUTION [J].
TANG, L ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1993, 65 (24) :3654-3668
[34]   Monitoring metal ion flux in reactions of metallothionein and drug-modified metallothionein by electrospray mass spectrometry [J].
Zaia, J ;
Fabris, D ;
Wei, D ;
Karpel, RL ;
Fenselau, C .
PROTEIN SCIENCE, 1998, 7 (11) :2398-2404
[35]   Electrospray mass spectrometry of fossil fuels [J].
Zhan, DL ;
Fenn, JB .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 194 (2-3) :197-208
[36]   Protonation in electrospray mass spectrometry: Wrong-way-round or right-way-round? [J].
Zhou, SL ;
Cook, KD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) :961-966
[37]  
2003, NIST CHEM WEBBOOK ST