On the effect of X-ray irradiation on the deformation and fracture behavior of human cortical bone

被引:151
作者
Barth, Holly D. [1 ,2 ,3 ]
Launey, Maximilien E. [1 ]
MacDowell, Alastair A. [2 ]
Ager, Joel W., III [1 ]
Ritchie, Robert O. [1 ,3 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Div Mat Sci, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Lab, Expt Syst Grp, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Dept Mat Sci & Engn, Berkeley, CA 94720 USA
关键词
Human cortical bone; X-ray radiation; Deformation; Toughness; Collagen; FATIGUE-CRACK-PROPAGATION; HUMAN CANCELLOUS BONE; AGE-RELATED-CHANGES; MECHANICAL-PROPERTIES; GAMMA-IRRADIATION; BIOMECHANICAL PROPERTIES; IONIZING-RADIATION; ALLOGRAFT BONE; COLLAGEN; TOUGHNESS;
D O I
10.1016/j.bone.2010.02.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In situ mechanical testing coupled with imaging using high-energy synchrotron X-ray diffraction or tomography is gaining in popularity as a technique to investigate micrometer and even sub-micrometer deformation and fracture mechanisms in mineralized tissues, such as bone and teeth. However, the role of the irradiation in affecting the nature and properties of the tissue is not always taken into account. Accordingly, we examine here the effect of X-ray synchrotron-source irradiation on the mechanistic aspects of deformation and fracture in human cortical bone. Specifically, the strength, ductility and fracture resistance (both work-of-fracture and resistance-curve fracture toughness) of human femoral bone in the transverse (breaking) orientation were evaluated following exposures to 0.05, 70, 210 and 630 kGrays (kGy) irradiation. Our results show that the radiation typically used in tomography imaging can have a major and deleterious impact on the strength, post-yield behavior and fracture toughness of cortical bone, with the severity of the effect progressively increasing with higher doses of radiation. Plasticity was essentially suppressed after as little as 70 kGy of radiation; the fracture toughness was decreased by a factor of five after 210 kGy of radiation. Mechanistically, the irradiation was found to alter the salient toughening mechanisms, manifest by the progressive elimination of the bone's capacity for plastic deformation which restricts the intrinsic toughening from the formation "plastic zones" around crack-like defects. Deep-ultraviolet Raman spectroscopy indicated that this behavior could be related to degradation in the collagen integrity. Published by Elsevier Inc.
引用
收藏
页码:1475 / 1485
页数:11
相关论文
共 84 条
[41]  
Kadler KE, 1996, BIOCHEM J, V316, P1
[42]  
Kennedy J.F., 2005, STERILISATION TISSUE
[43]   X-RAY TOMOGRAPHIC MICROSCOPY (XTM) USING SYNCHROTRON RADIATION [J].
KINNEY, JH ;
NICHOLS, MC .
ANNUAL REVIEW OF MATERIALS SCIENCE, 1992, 22 :121-152
[44]   The true toughness of human cortical bone measured with realistically short cracks [J].
Koester, K. J. ;
Ager, J. W., III ;
Ritchie, R. O. .
NATURE MATERIALS, 2008, 7 (08) :672-677
[45]   Inhomogeneous fibril stretching in antler starts after macroscopic yielding: Indication for a nanoscale toughening mechanism [J].
Krauss, Stefanie ;
Fratzl, Peter ;
Seto, Jong ;
Currey, John D. ;
Estevez, Jose A. ;
Funari, Sergio S. ;
Gupta, Himadri S. .
BONE, 2009, 44 (06) :1105-1110
[46]   Mechanistic aspects of the fracture toughness of elk antler bone [J].
Launey, M. E. ;
Chen, P-Y. ;
McKittrick, J. ;
Ritchie, R. O. .
ACTA BIOMATERIALIA, 2010, 6 (04) :1505-1514
[47]  
Launey ME, 2010, ANNU REV MATER RES, V40, P25, DOI 10.1146/annurev-matsci-070909-10442
[48]   On the Fracture Toughness of Advanced Materials [J].
Launey, Maximilien E. ;
Ritchie, Robert O. .
ADVANCED MATERIALS, 2009, 21 (20) :2103-2110
[49]   The current status of tissue regulation, procurement, processing, and sterilization [J].
McAllister, David R. ;
Joyce, Michael J. ;
Mann, Barton J. ;
Vangsness, C. Thomas, Jr. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (12) :2148-2158
[50]  
Mercury CS, 2008, AVIZO 3D VISUALIZATI