Glow discharge ionization source for liquid chromatography/particle beam mass spectrometry

被引:26
作者
Gibeau, TE [1 ]
Marcus, RK [1 ]
机构
[1] Clemson Univ, Howard L Hunter Chem Labs, Dept Chem, Clemson, SC 29634 USA
关键词
D O I
10.1021/ac0002691
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A detailed evaluation of the analytical characteristics of a liquid chromatography/particle beam-glow discharge mass spectrometry (LC/PB-GDMS) system is described for applications in the area of inorganic (free metals in solution) and organic compound analysis. A highly efficient particle beam interface is used to introduce analyte species into a glow discharge source for subsequent vaporization and ionization, The GD operating current and gas pressure were optimized, with the general responses found to be similar to those obtained previously for particulate matter analysis by this PB-GDMS system. The mass spectra obtained for inorganic species are comprised exclusively of the respective elements' isotopic patterns, with no evidence of appreciable oxide species formation. Organic species introduced into the discharge through the particle beam interface yield mass spectra that are virtually identical to those from standard electron impact (70 eV) ionization, An analytical response curve for caffeine, using 200-mu L (H2O/MeOH) injection volumes, showed less than 5% RSD for replicate injections over a concentration range of 10-500 ppm, with a detection limit of 13 ppb (2.7 ng) obtained for the caffeine molecular ion. Similarly, detection limits for Fe, Ag, and Cs ranged from 5.8 to 6.1 ppb (similar to 1 ng, each) in the injected volume. As an example of the feasibility of the PB-GDMS system as a detector for liquid chromatography, the separation and identification of the organic constituents in diet soda was performed.
引用
收藏
页码:3833 / 3840
页数:8
相关论文
共 37 条
[21]   RF-POWERED GLOW-DISCHARGES - ELEMENTAL ANALYSIS ACROSS THE SOLIDS SPECTRUM [J].
MARCUS, RK ;
HARVILLE, TR ;
MEI, Y ;
SHICK, CR .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :A902-A911
[22]  
MARCUS RK, 1993, GLOW DISCHARGE SPECT, pCH1
[23]   GLOW-DISCHARGE MASS-SPECTROMETRY OF SOME ORGANIC-COMPOUNDS [J].
MASON, R ;
MILTON, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 91 (02) :209-225
[24]   Applications of mass spectrometry in the trace element analysis of biological materials [J].
Moens, L .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :309-316
[25]  
Montaser A., 1998, INDUCTIVELY COUPLED
[26]  
*NAT I STAND TECHN, 1998, NIST CHEM WEBB
[27]   Radiofrequency glow discharge mass spectrometry for gas chromatographic detection: A new departure for elemental speciation studies [J].
Olson, LK ;
Belkin, M ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :491-496
[28]   Glow discharge mass spectrometric analysis of atmospheric particulate matter [J].
Schelles, W ;
Maes, KJR ;
DeGendt, S ;
VanGrieken, RE .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1136-1142
[29]   The use of a hollow cathode glow discharge (HCGD) as an atomic emission spectrometric element specific detector for chlorine and bromine in gas chromatography [J].
Schepers, C ;
Broekaert, JAC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (01) :61-65
[30]   AQUEOUS SAMPLE INTRODUCTION INTO A GLOW-DISCHARGE DEVICE VIA A PARTICLE BEAM INTERFACE [J].
STRANGE, CM ;
MARCUS, RK .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (04) :517-526