Comparison of a preliminary procedure for the general unknown screening of drugs and toxic compounds using a quadrupole-linear ion-trap mass spectrometer with a liquid chromatography-mass spectrometry reference technique

被引:62
作者
Marquet, P
Saint-Marcoux, F
Gamble, TN
Leblanc, JCY
机构
[1] Univ Hosp, Dept Pharmacol & Toxicol, Limoges, France
[2] MDS Sciex, Concord, ON, Canada
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 789卷 / 01期
关键词
general unknown screening; linear trap;
D O I
10.1016/S1570-0232(03)00071-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-tandem mass spectrometry (LC-MS-MS) might be a complement to GC-MS and HPLC-diode array detection for the general unknown screening (GUS) of drugs and toxic compounds, particularly when using information- or data-dependent acquisition (IDA or DDA), an auto-adaptive MS-MS product-ion scan mode where, at each unit time, the m/z ratios above a given intensity threshold are selected for fragmentation. A new quadrupole-linear ion-trap mass spectrometer (LC-QqQlinear ion-trap) was evaluated for GUS using IDA. For the first detection step (so-called "survey scan") the single quadrupole "enhanced" MS mode (EMS), where ions are accumulated then filtered in the Q3-linear ion-trap, was used. The so-called "enhanced" parent ion scan mode (EPI) used at two alternated fragmentation energies gave the best signal intensity and the best mass spectral information when adding mass spectra obtained in low and high fragmentation conditions, respectively, both in the positive (+20 and +50 eV) and negative (-15 and -40 eV) modes. Solid-phase extracts of serum spiked with eight test compounds (chosen for their retention times distributed along the 30-min long chromatogram and for ionising in both the positive and negative modes) were analysed in parallel with this LC-MS-MS technique and with a reference LC-MS method run on a single-quadrupole instrument where low and high in-source fragmentation conditions in the positive and the negative ion modes are alternated. A C-18, 5 mum (150 X 1 mm I.D.) column and a gradient elution of acetonitrile in pH 3, 2 mM ammonium formate, were used for both. Higher signal-to-noise ratios were obtained with the LC-QqQlinear ion-trap instrument than with the reference technique, resulting in mass spectra devoid of contaminant ions and at least as informative as the reconstructed single-MS spectra. After optimisation of the IDA intensity threshold for the detection of tiny chromatographic peaks in noise, five out of the eight compounds (milrinone, lorazepam, fluometuron, piretanide and warfarin) could be unambiguously identified at the concentration of 0.1 mg/l in serum, in the positive or negative modes, or in both, versus only two by LC-MS. All of them could be identified at 1 mg/l by both techniques. These preliminary results show that the sensitivity and mass structural information brought by this new LC-QqQlinear ion-trap instrument may help design an efficient toxicological GUS procedure. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:9 / 18
页数:10
相关论文
共 9 条
[1]  
Decaestecker TN, 2000, RAPID COMMUN MASS SP, V14, P1787, DOI 10.1002/1097-0231(20001015)14:19<1787::AID-RCM94>3.0.CO
[2]  
2-S
[3]  
*DRUGD SYST, 2002, MICROMEDEX
[4]  
Fitzgerald RL, 1999, CLIN CHEM, V45, P1224
[5]   Guidelines for the interpretation of analytical toxicology results and unit of measurement conversion factors [J].
Flanagan, RJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 :261-267
[6]   Is LC-MS suitable for a comprehensive screening of drugs and poisons in clinical toxicology? [J].
Marquet, P .
THERAPEUTIC DRUG MONITORING, 2002, 24 (01) :125-133
[7]   In-source CID mass spectral libraries for the "general unknown" screening of drugs and toxicants [J].
Marquet, P ;
Venisse, N ;
Lacassie, É ;
Lachâtre, G .
ANALUSIS, 2000, 28 (10) :925-934A
[8]  
VENISSE N, IN PRESS J ANAL TOXI
[9]   Tune compounds for electrospray ionisation/in-source collision-induced dissociation with mass spectral library searching [J].
Weinmann, W ;
Stoertzel, M ;
Vogt, S ;
Wendt, J .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :199-209