Effect of elasticity on wall shear stress inside cerebral aneurysm at anterior cerebral artery

被引:23
作者
Xu, Lijian [1 ]
Sugawara, Michiko [1 ]
Tanaka, Gaku [1 ]
Ohta, Makoto [2 ]
Liu, Hao [1 ]
Yamaguchi, Ryuhei [1 ]
机构
[1] Chiba Univ, Grad Sch Engn, Chiba, Japan
[2] Tohoku Univ, Inst Fluid Sci, Sendai, Miyagi 980, Japan
关键词
Cerebral aneurysm; elasticity; wall shear stress; PIV; CFD; hemodynamics; FLOW; HEMODYNAMICS; BIFURCATION; RUPTURE; MODEL; CFD;
D O I
10.3233/THC-161135
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
100404 [儿少卫生与妇幼保健学];
摘要
BACKGROUND: Many numerical studies have been published with respect to about flow structures around cerebral aneurysm assuming to be rigid. Furthermore, there is little experimental research concerning aneurysm with elastic wall. Wall shear stress in elastic wall comparing with rigid wall should be clarified in experimental approach and verified in CFD. OBJECTIVE: We have experimentally realized elastic aneurysm model accompanying with wall deformation. Wall shear stress was examined for both rigid and elastic aneurysm models in pulsatile flow. METHODS: Effect of elasticity on wall shear stress inside aneurysm induced at the apex of anterior cerebral artery was experimentally examined by particle image velocimetry in vitro. In order to adjust the wall deformation, the pressure adjustment chamber was specially equipped outside the aneurysm wall. RESULTS: Effect of elasticity on wall shear stress was noticed on the comparison with that of rigidity. Wall elasticity reduced the peak magnitude, the spatial and temporal averaged wall shear stress comparing with those of wall rigidity experimentally. These reductions were endorsed by fluid-structure interaction simulation. CONCLUSION: Elastic wall comparing with rigid wall would reduce the peak magnitude, the spatial and temporal averaged wall shear stress acting on vascular wall.
引用
收藏
页码:349 / 357
页数:9
相关论文
共 33 条
[1]
Acevedo-Bolton Gabriel, 2006, Neurosurgery, V59, pE429, DOI 10.1227/01.NEU.0000223495.39240.9A
[2]
Fluid-induced wall shear stress in anthropomorphic brain aneurysm models: MR phase-contrast study at 3 T [J].
Ahn, Sinyeob ;
Shin, Dongsuk ;
Tateshima, Satoshi ;
Tanishita, Kazuo ;
Vinuela, Fernando ;
Sinha, Shantanu .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) :1120-1130
[3]
Flow instability and wall shear stress variation in intracranial aneurysms [J].
Baek, H. ;
Jayaraman, M. V. ;
Richardson, P. D. ;
Karniadakis, G. E. .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2010, 7 (47) :967-988
[4]
Bando Y, 2006, T JSME B, V72, P2386
[5]
Clinical application of image-based CFD for cerebral aneurysms [J].
Cebral, J. R. ;
Mut, F. ;
Sforza, D. ;
Loehner, R. ;
Scrivano, E. ;
Lylyk, P. ;
Putman, C. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2011, 27 (07) :977-992
[6]
Cebral JR, 2005, AM J NEURORADIOL, V26, P2550
[7]
Morphology parameters for intracranial aneurysm rupture risk assessment [J].
Dhar, Sujan ;
Tremmel, Markus ;
Mocco, J. ;
Kim, Minsuok ;
Yamamoto, Junichi ;
Siddiqui, Adnan H. ;
Hopkins, L. Nelson ;
Meng, Hui ;
Derdeyn, Colin ;
Dacey, Ralph G., Jr. ;
Macdonald, R. Loch ;
Carter, Bob ;
Fernandez-Miranda, Juan C. ;
Dumont, Aaron S. ;
Kassell, Neal F. .
NEUROSURGERY, 2008, 63 (02) :185-197
[8]
High Wall Shear Stress and Spatial Gradients in Vascular Pathology: A Review [J].
Dolan, Jennifer M. ;
Kolega, John ;
Meng, Hui .
ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (07) :1411-1427
[9]
PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models [J].
Ford, Matthew D. ;
Nikolov, Hristo N. ;
Milner, Jaques S. ;
Lownie, Stephen P. ;
DeMont, Edwin M. ;
Kalata, Wojciech ;
Loth, Francis ;
Holdsworth, David W. ;
Steinman, David A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02)
[10]
STIFFNESS AND ELASTIC BEHAVIOR OF HUMAN INTRA-CRANICAL AND EXTRA-CRANIAL ARTERIES [J].
HAYASHI, K ;
HANDA, H ;
NAGASAWA, S ;
OKUMURA, A ;
MORITAKE, K .
JOURNAL OF BIOMECHANICS, 1980, 13 (02) :175-+