Simultaneous determination of lead(II) and cadmium(II) at a diacetyldioxime modified carbon paste electrode by differential pulse stripping voltammetry

被引:137
作者
Hu, CG [1 ]
Wu, KB [1 ]
Dai, X [1 ]
Hu, SS [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
diacetyldioxime; lead(Il); cadmium(ll); differential pulse stripping voltammetry; chemically modified electrode;
D O I
10.1016/S0039-9140(03)00116-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and effective chemically modified carbon paste electrode (CMCPE) for the simultaneous determination of lead(II) and cadmium(II) was developed in this work. The electrode was prepared by the addition of diacetyldioxime into a carbon paste mixture. Pb2+ and Cd2+ were preconcentrated on the surface of the modified electro de by complexing with diacetyldioxime and reduced at a negative potential (-1.10 V). Then the reduced products were oxidized by differential pulse stripping. The fact that two stripping-peaks appeared on the voltammograms at the potentials of - 0. 65 V (Cd2+) and -0.91 V (Pb2+) demonstrates the possibility of simultaneous determination of Pb2+ and Cd. Under the optimized working conditions, calibration graphs were linear in the concentration ranges of 1.0 x 10(-7)-1.5 x 10(-5) mol l(-1) (Pb2+) and 2.5 x 10(-7) -2.5 x 10(-5) Mol l(-1) (Cd2+) respectively. For 5 min preconcentration, detection limits of 1 x 10(-8) mol l(-1) (Pb2+) and 4 x 10(-8) mol l(-1) (Cd2+) were obtained at the signal noise ratio (SNR) of 3. To evaluate the reproducibility of the newly developed electrode, the measurements of 5 x 10(-7) Mol l(-1) Pb2+ and Cd2+ were parallel carried out for six times at different electrodes and the relative standard deviations were 2.9% (Pb2+) and 3.2%(Cd2+), respectively. Interferences by some metals were investigated. Only Ni2+ and Hg2+ apparently affected the peak currents of Pb2+ and Cd2+. The diacetyldioxime modified carbon paste electrode was applied to the determination of Pb2+ and Cd2+ in water samples. The results indicate that this electrode is sensitive and effective for the simultaneous determination of Pb2+ and Cd (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 30 条
[1]   VOLTAMMETRIC DETERMINATION OF TRACES OF NICKEL(II) AT A CHEMICALLY MODIFIED ELECTRODE BASED ON DIMETHYLGLYOXIME-CONTAINING CARBON PASTE [J].
BALDWIN, RP ;
CHRISTENSEN, JK ;
KRYGER, L .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1790-1798
[2]   Chemical accumulation and voltammetric determination of traces of nickel(II) at glassy carbon electrodes modified with dimethyl glyoxime containing polymer coatings [J].
Bing, C ;
Deen, R ;
Khang, GN ;
Sai, CL ;
Kryger, L .
TALANTA, 1999, 49 (03) :651-659
[3]   Characteristics of subtractive anodic stripping voltammetry of Pb and Cd at silver and gold electrodes [J].
Bonfil, Y ;
Brand, M ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2002, 464 (01) :99-114
[4]   Determination of nanomolar concentrations of lead and cadmium by anodic-stripping voltammetry at the silver electrode [J].
Bonfil, Y ;
Kirowa-Eisner, E .
ANALYTICA CHIMICA ACTA, 2002, 457 (02) :285-296
[5]   Nafion-coated mercury thin film electrodes for batch-injection analysis with anodic stripping voltammetry [J].
Brett, CMA ;
Brett, AMO ;
Matysik, FM ;
Matysik, S ;
Kumbhat, S .
TALANTA, 1996, 43 (11) :2015-2022
[6]   On-line preconcentration of lead and cadmium for flame atomic absorption spectrometry using a flow-through electrochemical microcell [J].
Bulska, E ;
Walcerz, M ;
Jedral, W ;
Hulanicki, A .
ANALYTICA CHIMICA ACTA, 1997, 357 (1-2) :133-140
[7]   Adsorption and electrochemical reduction of Co(II)-dimethylglyoxime on mercury [J].
Cordon, F ;
Ramírez, SA ;
Gordillo, GJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 534 (02) :131-141
[8]   Development and validation of a one-step immunoassay for determination of cadmium in human serum [J].
Darwish, IA ;
Blake, DA .
ANALYTICAL CHEMISTRY, 2002, 74 (01) :52-58
[9]   Simultaneous determination of trace amounts of cadmium, nickel and cobalt in water samples by adsorptive voltammetry using ammonium 2-amino-cyclopentene dithiocarboxylate as a chelating agent [J].
Ensafi, AA ;
Zarei, K .
TALANTA, 2000, 52 (03) :435-440
[10]   Anodic stripping voltammetry of lead and cadmium using a mercury film electrode and thiocyanate [J].
Fischer, E ;
van den Berg, CMG .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :273-280