Ridge number density:: A new parameter for in vivo bone structure analysis

被引:147
作者
Laib, A
Hildebrand, T
Häuselmann, HJ
Rüegsegger, P
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8044 Zurich, Switzerland
[2] Swiss Fed Inst Technol, Zurich, Switzerland
[3] Univ Zurich Hosp, Dept Rheumatol, CH-8091 Zurich, Switzerland
关键词
computed tomography (CT); bone microarchitecture; trabecular bone structure; quantitative bone morphology;
D O I
10.1016/S8756-3282(97)00205-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An advanced analysis of the mechanical properties of bone should include information about the microarchitecture of cancellous bone in addition to its density, It has recently been shown that high-resolution quantitative computed tomography and magnetic resonance imaging have the potential to assess such information in a noninvasive way in patients, Both techniques, however, lark sufficient spatial resolution to image the individual trabeculae with true precision, In this work, a new parameter, Ridge number density (RND), is introduced, RND is a measure for the trabecular number, which can be extracted directly from high-resolution three-dimensional (3D) images of patients, we applied the RND technique to a test group of nine healthy, postmenopausal women measured repetitively with a high-resolution 3D peripheral quantitative computed tomography (3D-pQCT) system with 165 x 165 x 165 mu m(3) voxel size, Simultaneously with the RND determination, the trabecular bone density (TBD) was also assessed in the same volume of interest, The examination site was the distal radius, The intersubject variability of the measured test group was 10.5% for RND and 26.3% for TBD, The root mean square error between first and second examinations (midterm reproducibility) was 1.6% and 1.1%, respectively, RND is determined independently front TBD and pertains to the structure of the cancellous bone, As such, it might add crucial information in cases where bone mass or bone density measurements alone give ambiguous results. (C) 1997 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:541 / 546
页数:6
相关论文
共 19 条
[1]   BONE-MINERAL CONTENT AND MECHANICAL STRENGTH OF FEMORAL-NECK [J].
DALEN, N ;
HELLSTROM, LG ;
JACOBSON, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1976, 47 (05) :503-508
[2]   ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[3]   RIDGES AND VALLEYS ON DIGITAL IMAGES [J].
HARALICK, RM .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1983, 22 (01) :28-38
[4]   CHARACTERIZATION OF MICROSTRUCTURAL ANISOTROPY IN ORTHOTROPIC MATERIALS USING A 2ND RANK TENSOR [J].
HARRIGAN, TP ;
MANN, RW .
JOURNAL OF MATERIALS SCIENCE, 1984, 19 (03) :761-767
[5]   THE ROLE OF 3-DIMENSIONAL TRABECULAR MICROSTRUCTURE IN THE PATHOGENESIS OF VERTEBRAL COMPRESSION FRACTURES [J].
KLEEREKOPER, M ;
VILLANUEVA, AR ;
STANCIU, J ;
RAO, DS ;
PARFITT, AM .
CALCIFIED TISSUE INTERNATIONAL, 1985, 37 (06) :594-597
[6]   EVALUATION OF TECHNICAL FACTORS AFFECTING THE QUANTIFICATION OF TRABECULAR BONE-STRUCTURE USING MAGNETIC-RESONANCE-IMAGING [J].
MAJUMDAR, S ;
NEWITT, D ;
JERGAS, M ;
GIES, A ;
CHIU, E ;
OSMAN, D ;
KELTNER, J ;
KEYAK, J ;
GENANT, H .
BONE, 1995, 17 (04) :417-430
[7]   NONINVASIVE BONE-BIOPSY - A NEW METHOD TO ANALYZE AND DISPLAY THE 3-DIMENSIONAL STRUCTURE OF TRABECULAR BONE [J].
MULLER, R ;
HILDEBRAND, T ;
RUEGSEGGER, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (01) :145-164
[8]  
Muller R, 1996, J BONE MINER RES, V11, P1745
[9]  
Muller R, 1996, Technol Health Care, V4, P113
[10]  
MUNCH B, 1991, THESIS ETH ZURICH