Sensitivity enhancement in the colorimetric detection of lead(II) ion using gallic acid-capped gold nanoparticles: Improving size distribution and minimizing interparticle repulsion

被引:171
作者
Huang, Kuan-Wei [1 ]
Yu, Cheng-Ju [1 ]
Tseng, Wei-Lung [1 ,2 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 804, Taiwan
[2] Natl Sun Yat Sen Univ, Kaohsiung Med Univ, Joint Res Ctr, Kaohsiung 804, Taiwan
关键词
Gold nanoparticles; Colorimetric detection; Gallic acid; Lead ions; Sensor; SELECTIVE FLUORESCENT CHEMOSENSOR; STRIPPING VOLTAMMETRY; PB2+; MERCURY; CITRATE; SENSOR; COMPLEXES; PB(II); BLOOD;
D O I
10.1016/j.bios.2009.09.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
We have developed a colorimetric assay for the highly sensitive and selective detection of Pb2+ by narrowing the size distribution of gallic acid-capped gold nanoparticles (GA-AuNPs) and minimizing electrostatic repulsion between each GA-AuNP. We unveil that the particle size and size distribution of GA-AuNPs could be controlled by varying the pH of HAuCl4 with fixed concentrations of HAuCl4 and GA. When the pH of the precursor solution (i.e., HAuCl4) was adjusted from 2.2 to 11.1, the average diameter of GA-AuNPs was decreased from 75.1 nm to 9.3 nm and their size distribution was reduced from 56.6-93.6 nm to 9.0-9.6 nm. The colorimetric sensitivity of the Pb2+-induced aggregation of GA-AuNPs could be improved using narrow size distribution of GA-AuNPs. Moreover, further enhancement of the colorimetric sensitivity of GA-AuNPs toward Pb2+ could be achieved by adding NaClO4 to minimize electrostatic repulsion between GA-AuNPs. which provide a small energy barrier for Pb2+ to overcome. Under the optimum conditions (1.0 mM NaClO4 and 20 mM formic acid at pH 4.5). the selectivity of 9.3 nm GA-AuNPs for Pb2+ over other metal ions in aqueous solutions is remarkably high, and its minimum detectable concentration for Pb2+ is 10 nM. We demonstrate the practicality of 9.3 nm GA-AuNPs for the determination of Pb2+ in drinking water. This approach offers several advantages, including simplicity (without temperature control), low cost (no enzyme or DNA), high sensitivity, high selectivity, and a large linear range (10.0-1000.0 nM). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:984 / 989
页数:6
相关论文
共 43 条
[21]
A highly sensitive and selective catalytic DNA biosensor for lead ions [J].
Li, J ;
Lu, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (42) :10466-10467
[22]
Selective determination of cysteine by resonance light scattering technique based on self-assembly of gold nanoparticles [J].
Li, ZP ;
Duan, XR ;
Liu, CH ;
Du, BA .
ANALYTICAL BIOCHEMISTRY, 2006, 351 (01) :18-25
[23]
Determination of cadmium, mercury and lead in seawater by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry [J].
Liu, HW ;
Jiang, SJ ;
Liu, SH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (09) :1367-1375
[24]
Stimuli-responsive disassembly of nanoparticle aggregates for light-up colorimetric sensing [J].
Liu, J ;
Lu, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (36) :12677-12683
[25]
A colorimetric lead biosensor using DNAzyme-directed assembly of gold nanoparticles [J].
Liu, JW ;
Lu, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (22) :6642-6643
[26]
Accelerated color change of gold nanoparticles assembled by DNAzymes for simple and fast colorimetric Pb2+ detection [J].
Liu, JW ;
Lu, Y .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (39) :12298-12305
[27]
Spectroelectrochemical sensing based on attenuated total internal reflectance stripping voltammetry. 2. Determination of mercury and lead [J].
Maghasi, AT ;
Conklin, SD ;
Shtoyko, T ;
Piruska, A ;
Richardson, JN ;
Seliskar, CJ ;
Heineman, WR .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1458-1465
[28]
Needleman H.L., 1992, HUMAN LEAD EXPOSURE
[29]
Use of gold nanoparticles to enhance capillary electrophoresis [J].
Neiman, B ;
Grushka, E ;
Lev, O .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5220-5227
[30]
On-line and in-situ detection of lead aerosols by plasma-spectroscopy and laser-excited atomic fluorescence spectroscopy [J].
Neuhauser, RE ;
Panne, U ;
Niessner, R ;
Petrucci, GA ;
Cavalli, P ;
Omenetto, N .
ANALYTICA CHIMICA ACTA, 1997, 346 (01) :37-48