High-definition freehand 3-D ultrasound

被引:120
作者
Treece, GM
Gee, AH
Prager, RW
Cash, CJC
Berman, LH
机构
[1] Dept Engn, Cambridge CB2 1PZ, England
[2] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
基金
英国工程与自然科学研究理事会;
关键词
3-D ultrasound; freehand scanning; musculoskeletal ultrasound;
D O I
10.1016/S0301-5629(02)00735-4
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper describes a high-definition freehand 3-D ultrasound (US) system, with accuracy surpassing that of previously documented systems. 3-D point location accuracy within a US data set can be achieved to within 0.5 mm. Such accuracy is possible through a series of novel system-design and calibration techniques. The accuracy is quantified using a purpose-built tissue-mimicking phantom, designed to create realistic clinical conditions without compromising the accuracy of the measurement procedure. The paper includes a thorough discussion of the various ways of measuring system accuracy and their relative merits; and compares, in this context, all recently documented freehand 3-D US systems. (E-mail: gmt11@eng.cam.ac.uk) (C) 2003 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:529 / 546
页数:18
相关论文
共 32 条
[1]   The impact of sound speed errors on medical ultrasound imaging [J].
Anderson, ME ;
McKeag, MS ;
Trahey, GE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 107 (06) :3540-3548
[2]   US artifacts: Effects on out-of-plane US images reconstructed from three-dimensional data sets [J].
Bailey, JE ;
Bude, RO ;
Tuthill, T .
RADIOLOGY, 2001, 218 (02) :592-597
[3]   Optimisation and evaluation of an electromagnetic tracking device for high-accuracy three-dimensional ultrasound imaging of the carotid arteries [J].
Barratt, DC ;
Davies, AH ;
Hughes, AD ;
Thom, SA ;
Humphries, KN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (07) :957-968
[4]   Three-dimensional freehand ultrasound: Image reconstruction and volume analysis [J].
Barry, CD ;
Allott, CP ;
John, NW ;
Mellor, PM ;
Arundel, PA ;
Thomson, DS ;
Waterton, JC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (08) :1209-1224
[5]  
BELOHLAVEK M, 1994, P SOC PHOTO-OPT INS, V2359, P680
[6]   Dynamic three-dimensional freehand echocardiography using raw digital ultrasound data [J].
Berg, S ;
Torp, H ;
Martens, D ;
Steen, E ;
Samstad, S ;
Hoivik, I ;
Olstad, B .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (05) :745-753
[7]   Systematic distortions in magnetic position digitizers [J].
Birkfellner, W ;
Watzinger, F ;
Wanschitz, F ;
Enislidis, G ;
Kollmann, C ;
Rafolt, D ;
Nowotny, R .
MEDICAL PHYSICS, 1998, 25 (11) :2242-2248
[8]  
Blackall JM, 2000, LECT NOTES COMPUT SC, V1935, P462
[9]   Calibration of three-dimensional ultrasound images for image-guided radiation therapy [J].
Bouchet, LG ;
Meeks, SL ;
Goodchild, G ;
Bova, FJ ;
Buatti, JM ;
Friedman, WA .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) :559-577
[10]   Analysis of geometrical distortion and statistical variance in length, area, and volume in a linearly scanned 3-D ultrasound image [J].
Cardinal, HN ;
Gill, JD ;
Fenster, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (06) :632-651