Tesio-Caths provide effective and safe long-term vascular access

被引:33
作者
Duncan, NDC
Singh, S
Cairns, TDH
Clark, M
El-Tayar, A
Griffith, M
Hakim, N
Hamady, M
McLean, AG
Papalois, V
Palmer, A
Taube, D
机构
[1] St Marys Hosp, Renal & Transplant Unit, London, England
[2] St Marys Hosp, Dept Radiol, London, England
关键词
access adequacy; central venous catheters; infections; patient survival; vascular access;
D O I
10.1093/ndt/gfh467
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Vascular access is judged on its ability to provide good dialysis adequacy, its durability and complication rates. Formation of a functional arteriovenous fistula is desirable but difficult to achieve in a significant proportion of patients. We report the large-scale use of Tesio-Caths, a twin-line single-lumen central venous catheter, to maximize dialysis adequacy where formation of an arteriovenous fistula was not possible. Methods. All patients who had Tesio-Caths inserted between 1 January 1999 and 1 October 2002 were studied. Results. Six hundred and twenty-three Tesio-Caths were inserted from 1 January 1999 to 1 October 2002 in 435 patients, generating 7464 patient months of follow-up. Five hundred and ninety-four out of 623 (95.3%) Tesio-Caths were immediately functional. Mean dialysis adequacy measured by single-pool Kt/V was 1.5 +/- 0.3 for all Tesio-Caths for the entire period of study, with 68% of Tesio-Caths delivering a Kt/V > 1.4. Cumulative functional Tesio-Cath survival to final failure was 77.8 and 44% at 1 and 3 years, respectively. Cumulative patient survival was 84.7, 71.4 and 63% at 1, 2 and 3 years, respectively. Access-related infection accounted for 0.28 admissions/1000 catheter days, and the death rate from access-related sepsis was 9.6 deaths/1000 patient years at risk. The admission rate for access dysfunction was 0.33/1000 patient years at risk. Conclusion. Tesio-Caths provide good dialysis adequacy for patients in whom an arteriovenous fistula cannot be formed. Patient and functional access survival for this group was comparable with current European data irrespective of vascular access type. Complication rates were acceptably low.
引用
收藏
页码:2816 / 2822
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 2001, AM J KIDNEY DIS, V37, pS137, DOI DOI 10.1016/S0272-6386(01)70007-8
[2]   Adequacy of haemodialysis with cuffed central-vein catheters [J].
Atherikul, K ;
Schwab, SJ ;
Conlon, PJ .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (03) :745-749
[3]   Effective flow performances and dialysis doses delivered with permanent catheters:: a 24-month comparative study of permanent catheters versus arterio-venous vascular accesses [J].
Canaud, B ;
Leray-Moragues, H ;
Kerkeni, N ;
Bosc, JY ;
Martin, K .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2002, 17 (07) :1286-1292
[4]   Permanent twin catheter: a vascular access option of choice for haemodialysis in elderly patients [J].
Canaud, B ;
Leray-Moragues, H ;
Garrigues, V ;
Mion, C .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 :82-88
[5]  
Daugirdas J T, 1995, Adv Ren Replace Ther, V2, P295
[6]   Type of vascular access and mortality in US hemodialysis patients [J].
Dhingra, RK ;
Young, EW ;
Hulbert-Shearon, TE ;
Leavey, SF ;
Port, FK .
KIDNEY INTERNATIONAL, 2001, 60 (04) :1443-1451
[7]   Infective endocarditis in dialysis patients: New challenges and old [J].
Doulton, T ;
Sabharwal, N ;
Cairns, HS ;
Schelenz, S ;
Eykyn, S ;
O'Donnell, P ;
Chambers, J ;
Austen, C ;
Goldsmith, DJA .
KIDNEY INTERNATIONAL, 2003, 64 (02) :720-727
[8]  
*ERA EDTA REG, 2003, ERA EDTA REG 2001 AN
[9]  
Hoen B, 1998, J AM SOC NEPHROL, V9, P869
[10]   Comparison of blood flow rates and hydraulic resistance between the Mahurkar catheter, the Tesio twin catheter, and the Ash Split Cath [J].
Mankus, RA ;
Ash, SR ;
Sutton, JM .
ASAIO JOURNAL, 1998, 44 (05) :M532-M534