Tesio-Caths provide effective and safe long-term vascular access

被引:33
作者
Duncan, NDC
Singh, S
Cairns, TDH
Clark, M
El-Tayar, A
Griffith, M
Hakim, N
Hamady, M
McLean, AG
Papalois, V
Palmer, A
Taube, D
机构
[1] St Marys Hosp, Renal & Transplant Unit, London, England
[2] St Marys Hosp, Dept Radiol, London, England
关键词
access adequacy; central venous catheters; infections; patient survival; vascular access;
D O I
10.1093/ndt/gfh467
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Vascular access is judged on its ability to provide good dialysis adequacy, its durability and complication rates. Formation of a functional arteriovenous fistula is desirable but difficult to achieve in a significant proportion of patients. We report the large-scale use of Tesio-Caths, a twin-line single-lumen central venous catheter, to maximize dialysis adequacy where formation of an arteriovenous fistula was not possible. Methods. All patients who had Tesio-Caths inserted between 1 January 1999 and 1 October 2002 were studied. Results. Six hundred and twenty-three Tesio-Caths were inserted from 1 January 1999 to 1 October 2002 in 435 patients, generating 7464 patient months of follow-up. Five hundred and ninety-four out of 623 (95.3%) Tesio-Caths were immediately functional. Mean dialysis adequacy measured by single-pool Kt/V was 1.5 +/- 0.3 for all Tesio-Caths for the entire period of study, with 68% of Tesio-Caths delivering a Kt/V > 1.4. Cumulative functional Tesio-Cath survival to final failure was 77.8 and 44% at 1 and 3 years, respectively. Cumulative patient survival was 84.7, 71.4 and 63% at 1, 2 and 3 years, respectively. Access-related infection accounted for 0.28 admissions/1000 catheter days, and the death rate from access-related sepsis was 9.6 deaths/1000 patient years at risk. The admission rate for access dysfunction was 0.33/1000 patient years at risk. Conclusion. Tesio-Caths provide good dialysis adequacy for patients in whom an arteriovenous fistula cannot be formed. Patient and functional access survival for this group was comparable with current European data irrespective of vascular access type. Complication rates were acceptably low.
引用
收藏
页码:2816 / 2822
页数:7
相关论文
共 20 条
[11]   Catheter-related bacteremia and outcome of attempted catheter salvage in patients undergoing hemodialysis [J].
Marr, KA ;
Sexton, DJ ;
Conlon, PJ ;
Corey, GR ;
Schwab, SJ ;
Kirkland, KB .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :275-+
[12]   Predictors of adequacy of arteriovenous fistulas in hemodialysis patients [J].
Miller, PE ;
Tolwani, A ;
Luscy, CP ;
Deierhoi, MH ;
Bailey, R ;
Redden, DT ;
Allon, M .
KIDNEY INTERNATIONAL, 1999, 56 (01) :275-280
[13]   Infectious complications of the hemodialysis access [J].
Nassar, GM ;
Ayus, JC .
KIDNEY INTERNATIONAL, 2001, 60 (01) :1-13
[14]  
*NIH NAT I DIAB DI, 2003, USRDS REN DAT SYST U
[15]   Vascular access and increased risk of death among hemodialysis patients [J].
Pastan, S ;
Soucie, JM ;
McClellan, WM .
KIDNEY INTERNATIONAL, 2002, 62 (02) :620-626
[16]   Vascular access use in Europe and the United States: Results from the DOPPS [J].
Pisoni, RL ;
Young, EW ;
Dykstra, DM ;
Greenwood, RN ;
Hecking, E ;
Gillespie, B ;
Wolfe, RA ;
Goodkin, DA ;
Held, PJ .
KIDNEY INTERNATIONAL, 2002, 61 (01) :305-316
[17]   Long-term performance and complications of the Tesio twin catheter system for hemodialysis access [J].
Prabhu, PN ;
Kerns, SR ;
Sabatelli, FW ;
Hawkins, IF ;
Ross, EA .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 30 (02) :213-218
[18]   A randomized, prospective evaluation of the Tesio, Ash split, and Opti-flow hemodialysis catheters [J].
Richard, HM ;
Hastings, GS ;
Boyd-Kranis, RL ;
Murthy, R ;
Radack, DM ;
Santilli, JG ;
Ostergaard, C ;
Coldwell, DM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (04) :431-435
[19]   Silastic cuffed catheters for hemodialysis vascular access: Thrombolytic and mechanical correction of malfunction [J].
Suhocki, PV ;
Conlon, PJ ;
Knelson, MH ;
Harland, R ;
Schwab, SJ .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 28 (03) :379-386
[20]   DOUBLE CATHETERIZATION OF THE INTERNAL JUGULAR-VEIN FOR HEMODIALYSIS - INDICATIONS, TECHNIQUES, AND CLINICAL-RESULTS [J].
TESIO, F ;
DEBAZ, H ;
PANARELLO, G ;
CALIANNO, G ;
QUAIA, P ;
RAIMONDI, A ;
SCHINELLA, D .
ARTIFICIAL ORGANS, 1994, 18 (04) :301-304