Surface-modified poly(methyl methacrylate) capillary electrophoresis microchips for protein and peptide analysis

被引:124
作者
Liu, JK [1 ]
Pan, T [1 ]
Woolley, AT [1 ]
Lee, ML [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
关键词
D O I
10.1021/ac040094l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polymeric materials have emerged as appealing alternatives to conventional inorganic substrates for the fabrication of microscale analytical systems; however, native polymeric surfaces typically require covalent modification to ensure optimum biocompatibility. 2-Bromoisobutyryl bromide was immobilized on poly(methyl methacrylate) (PMMA) substrates activated using an oxygen plasma. Atom-transfer radical polymerization was then performed to graft poly(ethylene glycol) (PEG) on the PMMA surface. PMMA microcapillary electrophoresis (muCE) devices made with the covalently modified surfaces exhibited substantially reduced electroosmotic flow and nonspecific adsorption of proteins on microchannel surfaces. Experiments using fluorescein isothiocyanate-conjugated bovine serum albumin indicated that both column efficiency and migration time reproducibility were 1 order of magnitude better with derivatized compared to untreated PMMAmuCE chips. Fast, reproducible, and efficient separations of proteins and peptides were demonstrated using the PEG-grafted PMMA muCE chips. All analyses were completed in less than 60 s, and separation efficiencies as high as 5.2 x 10(4) plates for a 3.5-cm-long separation channel were obtained. These results demonstrate the general applicability of surface-grafted PMMA microdevices for a broad range of protein analyses.
引用
收藏
页码:6948 / 6955
页数:8
相关论文
共 56 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Plastic microfluidic devices modified with polyelectrolyte multilayers [J].
Barker, SLR ;
Tarlov, MJ ;
Canavan, H ;
Hickman, JJ ;
Locascio, LE .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4899-4903
[3]   Surface modification in microchip electrophoresis [J].
Belder, D ;
Ludwig, M .
ELECTROPHORESIS, 2003, 24 (21) :3595-3606
[4]   Plastic advances microfluidic devices. [J].
Boone, T ;
Fan, ZH ;
Hooper, H ;
Ricco, A ;
Tan, HD ;
Williams, S .
ANALYTICAL CHEMISTRY, 2002, 74 (03) :78A-86A
[5]  
Brandup J., 1999, POLYM HDB, V4th
[6]   ATRP grafting from cellulose fibers to create block-copolymer grafts [J].
Carlmark, A ;
Malmström, EE .
BIOMACROMOLECULES, 2003, 4 (06) :1740-1745
[7]   Ultrafast analysis of oligosaccharides on microchip with light-emitting diode confocal fluorescence detection [J].
Dang, F ;
Zhang, L ;
Hagiwara, H ;
Mishina, Y ;
Baba, Y .
ELECTROPHORESIS, 2003, 24 (04) :714-721
[8]   Microchannel wall coatings for protein separations by capillary and chip electrophoresis [J].
Doherty, EAS ;
Meagher, RJ ;
Albarghouthi, MN ;
Barron, AE .
ELECTROPHORESIS, 2003, 24 (1-2) :34-54
[9]  
Dou YH, 2002, ELECTROPHORESIS, V23, P3558, DOI 10.1002/1522-2683(200210)23:20<3558::AID-ELPS3558>3.0.CO
[10]  
2-#