Design and evaluation of an ultrasound-based bladder volume monitor

被引:27
作者
Kristiansen, NK [1 ]
Djurhuus, JC
Nygaard, H
机构
[1] Aarhus Univ Hosp, Inst Clin, Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Cardiothorar & Vasc Surg, Aarhus, Denmark
[3] Univ Coll Aarhus, Dept Elect & Informat Technol, Aarhus, Denmark
关键词
bladder scanner; ultrasound; bladder volume;
D O I
10.1007/BF02345209
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Ultrasonic bladder volume monitors have successfully been used in the diagnosis and treatment of various urological disorders. Ultrasonic bladder monitors have been developed but they have either been too bulky or too simple and inaccurate. A new, wearable ultrasonic bladder volume monitor has been designed for urological patients. The instrument consists of seven phased-array ultrasonic transducers ergonomically arranged in a circular pattern to optimise detection of the bladder walls perpendicular to the abdominal wall. A Bluetooth radio link was used to transmit data to a laptop computer, where the main signal processing was performed. After detection of bladder surface points, a three-dimensional convex hull representing the bladder was generated, and the volume was estimated. Accuracy, precision, drift over time, temperature dependency and dynamic performance were evaluated using ultrasound phantoms. Furthermore, the system was tested on one volunteer using magnetic resonance imaging (MRI) as reference. The apparatus showed no significant drift, systematic error or temperature effects. Percentage error during static volume measurements had a 95% central prediction interval of +/- 7.5% and mean absolute percentage error of 2.9%. The dynamic performance analysis showed linearity in the analysed volume interval. The in vivo study showed a high degree of correlation (R-2 = 0.99) between the volume measured using MRI and that measured with the apparatus.
引用
收藏
页码:762 / 769
页数:8
相关论文
共 21 条
[1]   Clinical utility of a portable ultrasound device in intermittent catheterization [J].
Anton, HA ;
Chambers, K ;
Clifton, J ;
Tasaka, J .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (02) :172-175
[2]   The Quickhull algorithm for convex hulls [J].
Barber, CB ;
Dobkin, DP ;
Huhdanpaa, H .
ACM TRANSACTIONS ON MATHEMATICAL SOFTWARE, 1996, 22 (04) :469-483
[3]   Bladder shape impact on the accuracy of ultrasonic estimation of bladder volume [J].
Bih, LI ;
Ho, CC ;
Tsai, SJ ;
Lai, YC ;
Chow, W .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (12) :1553-1556
[4]  
Binard J E, 1996, J Spinal Cord Med, V19, P194
[5]   AN EASILY MADE, LOW-COST, TISSUE-LIKE ULTRASOUND PHANTOM MATERIAL [J].
BUDE, RO ;
ADLER, RS .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (04) :271-273
[6]  
CARDENAS DD, 1988, ARCH PHYS MED REHAB, V69, P514
[7]   From time dependent intermittent selfcatheterisation to volume dependent selfcatheterisation in Multiple Sclerosis using the PCI 5000 Bladdermanager(R) [J].
DeRidder, D ;
VanPoppel, H ;
Baert, L ;
Binard, J .
SPINAL CORD, 1997, 35 (09) :613-616
[8]  
Dipankar G., 1990, U.S. Patent, Patent No. [4,926,871, 4926871]
[9]   BLADDER VOLUME SENSING BY LOCAL DISTENSION MEASUREMENT [J].
DREHER, RD ;
BRADLEY, WE ;
TIMM, GW .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1972, BM19 (03) :247-&
[10]   ACCURACY AND REPEATABILITY OF BLADDER VOLUME MEASUREMENT USING ULTRASONIC-IMAGING [J].
GRIFFITHS, CJ ;
MURRAY, A ;
RAMSDEN, PD .
JOURNAL OF UROLOGY, 1986, 136 (04) :808-812