Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; First clinical results and comparison with electronic portal-imaging device

被引:135
作者
Borst, Gerben R. [1 ]
Sonke, Jan-Jakob [1 ]
Betgen, Anja [1 ]
Remeijer, Peter [1 ]
Van Herk, Marcel [1 ]
Lebesque, Joos V. [1 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 68卷 / 02期
关键词
cone-beam CT; radiotherapy; lung cancer; setup error; portal images;
D O I
10.1016/j.ijrobp.2007.01.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Kilovoltage cone-beam computed tomography (CBCT) has been developed to provide accurate soft-tissue and bony setup information. We evaluated clinical CBCT setup data and compared CBCT measurements with electronic portal imaging device (EPID) images for lung cancer patients. Methods and Materials: The setup error for CBCT scans at the treatment unit relative to the planning CT was measured for 62 patients (524 scans). For 19 of these patients (172 scans) portal images were also made. The mean, systematic setup error (1), and random setup error (sigma) were calculated for the CBCT and the EPID. The differences between CBCT and EPID and the rotational setup error derived from the CBCT were also evaluated. An offline shrinking action level correction protocol, based on the CBCT measurements, was used to reduce systematic setup errors and the impact of this protocol was evaluated. Results: The CBCT setup errors were significantly larger than the EPID setup errors for the cranial- caudal and anterior-posterior directions (p < 0.05). The mean overall setup errors after correction measured with the CBCT were 0.2 mm (Sigma. 1.6 mm, sigma = 2.9 mm) in the left-right, -0.8 mm (Sigma = 1.7 mm, or = 4.0 mm) in cranial-caudal and 0.0 mm (Sigma. 1.5 mm, sigma = 2.0 mm) in the anterior-posterior direction. Using our correction protocol only 2 patients had mean setup errors larger than 5 mm, without this correction protocol 51% of the patients would have had a setup error larger than 5 mm. Conclusion: Use of CBCT scans provided more accurate information concerning the setup of lung cancer patients than did portal imaging. (C) 2007 Elsevier Inc.
引用
收藏
页码:555 / 561
页数:7
相关论文
共 24 条
[1]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[2]  
Betgen A, 2004, INT WORKSH EL PORT I
[3]   Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning [J].
de Boer, HCJ ;
De Koste, JRV ;
Senan, S ;
Visser, AG ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :857-868
[4]  
de Koste JRV, 2003, INT J RADIAT ONCOL, V55, P804, DOI 10.1016/S0630-3016(02)04285-2
[5]   The effect of breathing and set-up errors on the cumulative dose to a lung tumor [J].
Engelsmann, M ;
Damen, EMF ;
De Jaeger, K ;
van Ingen, KM ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) :95-105
[6]   Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer [J].
Erridge, SC ;
Seppenwoolde, Y ;
Muller, SH ;
van Herk, M ;
De Jaeger, K ;
Belderbos, JSA ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) :75-85
[7]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[8]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[9]   Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors [J].
Guckenberger, Matthias ;
Meyer, Juergen ;
Wilbert, Juergen ;
Baier, Kurt ;
Mueller, Gerd ;
Wulf, Joern ;
Flentje, Michael .
ACTA ONCOLOGICA, 2006, 45 (07) :897-906
[10]   The variation in biological effectiveness of X-rays and gamma rays with energy [J].
Hill, MA .
RADIATION PROTECTION DOSIMETRY, 2004, 112 (04) :471-481