IVBTMc, A Monte Carlo dose calculation tool for intravascular brachytherapy

被引:7
作者
Chibani, O [1 ]
Li, XA
机构
[1] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
[2] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
关键词
intravascular brachytherapy; Monte Carlo; dosimetry; heterogeneity; calcified plaque; source curvature;
D O I
10.1118/1.1528177
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
A new Monte Carlo code (IVBTMC) is developed for accurate dose calculations in intravascular brachytherapy (IVBT). IVBTMC calculates the dose distribution of a brachytherapy source with arbitrary size and curvature in a general three-dimensional heterogeneous medium. Both beta and gamma sources are considered. IVBTMC is based on a modified version of the EGSNRC code. A voxel-based geometry is used to describe the target medium incorporating heterogeneities with arbitrary composition and shape. The source term is modeled using appropriate phase-space data. The phase-space data are calculated for three widely used sources ((32)p, Sr-90/Y-90, and Ir-192). To speed up dose calculations for gamma sources, a special version of IVBTMC based on the kerma approximation is developed. The accuracy of the phase-space data model is verified and IVBTMC is validated against other Monte Carlo codes and against reported measurements using radio-chromic films. To illustrate the IVBTMC capabilities, a variety of examples are treated. 32p, 90Sr/90Y, and Ir-192 sources with different lengths and degrees of curvature are considered. Calcified plaques with regular and irregular shapes are modeled. The dose distributions are calculated with a spatial resolution ranging between 0.1 and 0.5 mm. They are presented in terms of isodose contour plots. The dosimetric effects of the source curvature and/or the presence of calcified plaques are discussed. In conclusion, IVBTMC has the capability to perform high-precision IVBT dose calculations taking into account the realistic configurations of both the source and the target medium. Key Words: Intravascular Brachytherapy, Monte Carlo, Dosimetry, Heterogeneity, Calcified Plaque, Source curvature. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:44 / 51
页数:8
相关论文
共 40 条
[1]
Intracoronary radiation for prevention of restenosis - Dose perturbations caused by stents [J].
Amols, HI ;
Trichter, F ;
Weinberger, J .
CIRCULATION, 1998, 98 (19) :2024-2029
[2]
Dosimetric considerations for catheter-based beta and gamma emitters in the therapy of neointimal hyperplasia in human coronary arteries [J].
Amols, HI ;
Zaider, M ;
Weinberger, J ;
Ennis, R ;
Schiff, PB ;
Reinstein, LE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (04) :913-921
[3]
[Anonymous], 2000, MCNP GEN MONTE CARLO, DOI DOI 10.1016/J.CCLET.2011.04.015
[4]
[Anonymous], 1995, TABLES XRAY MASS ATT
[5]
Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations [J].
Bohm, TD ;
Mourtada, FA ;
Das, RK .
MEDICAL PHYSICS, 2001, 28 (08) :1770-1775
[6]
Dosimetric effects of source-offset in intravascular brachytherapy [J].
Chibani, O ;
Li, XA .
MEDICAL PHYSICS, 2002, 29 (04) :530-537
[7]
New electron backscatter correction factors for accurate skin depth dose calculation from skin contamination by hot particles [J].
Chibani, O .
HEALTH PHYSICS, 2001, 81 (04) :419-425
[8]
ELECTRON DEPTH-DOSE DISTRIBUTIONS IN WATER, IRON AND LEAD - THE GEPTS SYSTEM [J].
CHIBANI, O .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 101 (04) :357-378
[9]
NEW ELECTRON MULTIPLE-SCATTERING DISTRIBUTIONS FOR MONTE-CARLO TRANSPORT SIMULATION [J].
CHIBANI, O ;
PATAU, JP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1994, 94 (1-2) :1-10
[10]
New photon exposure buildup factors [J].
Chibani, O .
NUCLEAR SCIENCE AND ENGINEERING, 2001, 137 (02) :215-225