Analysis of recombinant human growth hormone by capillary electrophoresis with bilayer-coated capillaries using UV and MS detection

被引:54
作者
Catai, Jonatan R.
Torano, Javier Sastre
Jongen, Peter M. J. M.
de Jong, Gerhardus J.
Somsen, Govert W.
机构
[1] Univ Utrecht, Div Biomed Anal, NL-3508 TB Utrecht, Netherlands
[2] Natl Inst Publ Hlth & Environm, Ctr Biol Med & Med Technol, NL-3720 BA Bilthoven, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 852卷 / 1-2期
关键词
capillary electrophoresis; mass spectrometry; recombinant human growth hormone; biopharmaceutical; protein stability; bilayer coating;
D O I
10.1016/j.jchromb.2007.01.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The characterization of recombinant human growth hormone (rhGH; somatropin) by capillary electrophoresis (CE) with UV-absorbance and mass spectrometric (MS) detection using capillaries noncovalently coated with polybrene (PB) and poly(vinyl sulfortic acid) (PVS) is demonstrated. Compared with bare fused-silica capillaries, PB-PVS coated capillaries yielded more favorable migration-time reproducibilities and higher separation efficiencies. Optimal separation conditions for the bilayer-coated capillaries comprised a background electrolyte (BGE) of 400 mM Tris phosphate (pH 8.5) yielding migration-time R.S.D.s of less than 1.0% and plate numbers above 300,000 for intact rhGH. The protein was also analyzed using the CE method described in the European Pharmacopoeia (Ph. Eur.) monograph. The pharmacopoeial method gave much longer analysis times (22 min versus 8 min), lower resolution and plate numbers, and consecutive shifts in migration time for rhGH, indicating possible interactions between the protein and the inner capillary wall. Due to stable migration times obtained with the coated capillaries, reliable profiling and quantification of rhGH and its byproducts in time was possible. Analysis of thermally degraded rhGH revealed the formation of two main degradation products. CE-mass spectrometry (MS) of this sample, using a PB-PVS coated capillary and a BGE of 75 mM ammonium formate (pH 8.5), suggests that these products are desamido forms of rhGH. Analyses of expired rhGH preparations with CE-Uv and CE-MS indicated the presence of both deamidation and oxidation products. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 166
页数:7
相关论文
共 38 条
[21]  
Lagu AL, 1999, ELECTROPHORESIS, V20, P3145, DOI 10.1002/(SICI)1522-2683(19991001)20:15/16<3145::AID-ELPS3145>3.0.CO
[22]  
2-0
[23]   KINETIC STUDY OF DEAMIDATION OF GROWTH HORMONE AND PROLACTIN [J].
LEWIS, UJ ;
CHEEVER, EV ;
HOPKINS, WC .
BIOCHIMICA ET BIOPHYSICA ACTA, 1970, 214 (03) :498-&
[24]   STABILITY OF PROTEIN PHARMACEUTICALS [J].
MANNING, MC ;
PATEL, K ;
BORCHARDT, RT .
PHARMACEUTICAL RESEARCH, 1989, 6 (11) :903-918
[25]   Separation of recombinant human growth hormone from Escherichia coli cell pellet extract by capillary zone electrophoresis [J].
McNerney, TM ;
Watson, SK ;
Sim, JH ;
Bridenbaugh, RL .
JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) :223-229
[26]   COMPARISON OF REVERSED-PHASE AND ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE ANALYSIS OF HUMAN GROWTH-HORMONES [J].
PATIENCE, RL ;
REES, LH .
JOURNAL OF CHROMATOGRAPHY, 1986, 352 :241-253
[27]  
Patrick JS, 2001, ELECTROPHORESIS, V22, P4179, DOI 10.1002/1522-2683(200111)22:19<4179::AID-ELPS4179>3.0.CO
[28]  
2-8
[29]  
Pearlman R, 1993, Pharm Biotechnol, V5, P1
[30]   Separation techniques hyphenated to electrospray-tandem mass spectrometry in proteomics:: Capillary electrophoresis versus nanoliquid chromatography [J].
Pelzing, M ;
Neusüss, C .
ELECTROPHORESIS, 2005, 26 (14) :2717-2728