Improvement of flow and pressure controls in diffusion-tube humidity generator: Performance evaluation of trace-moisture generation using cavity ring-down spectroscopy

被引:18
作者
Abe, Hisashi [1 ]
Kitano, Hiroshi [1 ]
机构
[1] AIST, NMIJ, Tsukuba, Ibaraki 3058563, Japan
关键词
humidity standard; diffusion tube; magnetic suspension balance; trace moisture; sensor calibration; critical flow Venturi nozzle;
D O I
10.1016/j.sna.2006.12.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A system of flow and pressure controls for a magnetic suspension balance/diffusion-tube humidity generator (MSB/DTG) has been developed to realize a humidity standard in the trace-moisture region. The system essentially consists of a pressure regulator combined with a piezo valve, and adopts a simple stepwise change in the total flow rate. It has been demonstrated that the uncertainty of evaporation rates is greatly reduced by applying buoyancy correction to mass data measured with the MSB. Using the system and buoyancy-corrected data, the negative effect on the MSB/DTG observed upon changing the total flow rate become negligible. The relative standard uncertainty of total flow rates is evaluated using mass flow meters composed of critical flow Venturi nozzles to be less than or equal to 0.22%. The uncertainty of humidity generation has been significantly reduced by improvements introduced in this work. A comparison between humidity generated with the DTG and humidity measured with a moisture analyzer (MA) based on cavity ring-down spectroscopy is presented in the amount-of-substance fraction range between 10 nmol/mol and 250 nmol/mol. The results of the comparison confirm that the DTG is capable of producing a trace-moisture gas down to approximately 10 nmol/mol, and of easily varying and controlling the amount-of-substance fraction of water using the system. The sources of bias observed in the MA reading are attributable mainly to systematic errors in the temperature of the absorption cell and absorption cross section used to calculate the water concentration with the MA. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:723 / 729
页数:7
相关论文
共 20 条
[1]   Development of humidity standard in trace-moisture region: Characteristics of humidity generation of diffusion tube humidity generator [J].
Abe, H ;
Kitano, H .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 128 (01) :202-208
[2]   Cavity ring-down spectroscopy: Experimental schemes and applications [J].
Berden, G ;
Peeters, R ;
Meijer, G .
INTERNATIONAL REVIEWS IN PHYSICAL CHEMISTRY, 2000, 19 (04) :565-607
[3]   Using small sonic nozzles as secondary flow standards [J].
Bignell, N .
FLOW MEASUREMENT AND INSTRUMENTATION, 2000, 11 (04) :329-337
[4]   EQUATION FOR THE DETERMINATION OF THE DENSITY OF MOIST AIR (1981/91) [J].
DAVIS, RS .
METROLOGIA, 1992, 29 (01) :67-70
[5]   CALCULATED TABULATIONS OF H2O LINE BROADENING BY H2O,N2,O2, AND CO2 AT HIGH-TEMPERATURE [J].
DELAYE, C ;
HARTMANN, JM ;
TAINE, J .
APPLIED OPTICS, 1989, 28 (23) :5080-5087
[6]   Techniques for the measurement of trace moisture in high-purity electronic specialty gases [J].
Funke, HH ;
Grissom, BL ;
McGrew, CE ;
Raynor, MW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (09) :3909-3933
[7]   EQUATION FOR THE DETERMINATION OF THE DENSITY OF MOIST AIR (1981) [J].
GIACOMO, P .
METROLOGIA, 1982, 18 (01) :33-40
[8]   Development of a transfer standard with sonic Venturi nozzles for small mass flow rates of gases [J].
Hayakawa, M ;
Ina, Y ;
Yokoi, Y ;
Takamoto, M ;
Nakao, S .
FLOW MEASUREMENT AND INSTRUMENTATION, 2000, 11 (04) :279-283
[9]  
ISO IEC OIML BIPM, 1995, GUID EXPR UNC MEAS
[10]   Comparison of semiclassical line-shape models to rovibrational H2O spectra measured by frequency-stabilized cavity ring-down spectroscopy -: art. no. 012507 [J].
Lisak, D ;
Hodges, JT ;
Ciurylo, R .
PHYSICAL REVIEW A, 2006, 73 (01)